Background:Harvest of hematopoietic progenitor cells via leukapheresis is being used increasingly for transplants in India. Adequate yield of cells per kilogram body weight of recipient is required for successful engraftment. Collection efficiency (CE) is an objective quality parameter used to assess the quality of leukapheresis program. In this study, we calculated the CE of the ComTec cell separator (Fresenius Kabi, Germany) using two different formulae (CE1 and CE2) and analyzed various patient and procedural factors, which may affect it.Materials and Methods:One hundred and one consecutive procedures in 77 autologous donors carried out over 3 years period were retrospectively reviewed. Various characteristics like gender, age, weight, disease status, hematocrit, preprocedure total leukocyte count, preprocedure CD34 positive (CD34+) cells count, preprocedure absolute CD34+ cell count and processed apheresis volume effect on CE were compared. CE for each procedure was calculated using two different formulae, and results were compared using statistical correlation and regression analysis.Results:The mean CE1 and CE2 was 41.2 and 49.1, respectively. CE2 appeared to be more accurate indicator of overall CE as it considered the impact of continued mobilization of stem cells during apheresis procedure, itself. Of all the factors affecting CE, preprocedure absolute CD34+ was the only independent factor affecting CE.Conclusion:The only factor affecting CE was preprocedure absolute CD34+ cells. Though the mean CE2 was higher than CE1, it was not statistically significant.
Background:A rule called “30-min rule” defines that red cell unit cannot be used if it has been out of blood bank refrigerator for over 30 min. This rule is useful to guide initiation of transfusion, but is inadequate for deciding whether to reuse or discard units received-back at blood transfusion services (BTS). A simple cost-effective temperature-sensitive indicator was evaluated to decide upon reuse (cold chain was uninterrupted) or discard (where cold chain was interrupted) in a simulation exercise.Materials and Methods:Temperature-sensitive indicators TH-F™ that irreversibly changed color from white to red demonstrated that heat excursion has occurred and the cumulative temperature has exceeded 10°C for over 30 min, were used in outdated red cells for simulating units, which are not used and received-back. These units were also tagged with a standard temperature monitoring device, which was a re-usable credit card sized device, which would log the actual time and temperature. In few units percent hemolysis was also calculated.Results:Statistically insignificant elevation in average temperature was noted in 102 simulated units at the time of return to BTS (Δ 0.04°C), despite the fact that these units were in the transport box for over 4 h. The average supernatant hemoglobin in these units was 0.24%, much below the prescribed threshold.Conclusion:Transportation of blood in controlled conditions with temperature-sensitive indicator is a cost-effective model to save blood, a precious human resource.
Background and aims
Although desensitization is well established, concerns about graft outcome, patient survival and rejection still exist. The present study aims at comparing outcomes of renal transplant recipients across simultaneous ABO and human leukocyte antigen (HLA) incompatibility barriers to those with ABO or HLA incompatibility alone.
Materials and methods
This was a retrospective study conducted from October 2015 to December 2018. All patients with a clinical diagnosis of chronic kidney disease, who were prospective HLA incompatible (HLAi) and/or ABO incompatible (ABOi) renal transplant recipients were included. A total of 400 cases including 36 ABOi transplants, 154 HLAi transplants, 10 simultaneously ABO and HLA incompatible transplants, and 200 ABO (ABOc) and HLA (HLAc) compatible kidney transplants from living donors were included.
Results
There were significantly more number of blood transfusions, previous transplants and pregnancies in HLAi transplant recipients relative to the ABOi or the control group. Mean number of therapeutic plasma exchange procedures per patient and mean plasma volume processed per procedure were slightly higher in the ABOi + HLAi category. The incidence of graft dysfunction due to suspected antibody‐mediated rejection during first year was highest in the ABOi + HLAi group, followed by ABOc + HLAi and ABOi + HLAc, lowest in the ABOc + HLAc category. Mean time to first episode of graft dysfunction was significantly shorter with incompatible transplants. There were no kidney transplant recipient deaths in the study.
Conclusion
Patient outcome and graft outcomes observed with incompatible transplants were not worse than those observed with compatible transplants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.