Intense sound levels produced by engineering equipment have become an acute issue. As most of engineering equipment require air supply, exhaust and good ventilation, it is not possible to control the noise by covering them with tight hoods. Louver with blades covered with acoustic materials
and gaps that enable free circu- lation of air are used to this end. Three louver configurations were tested in the semi-anechoic chamber: bare metal louver blades, louver with blades covered with 20-mm-thick polystyrene foam slabs on both sides, and louver with blades covered with 15-mm-thick
glass wool slab. According to the test results, louver with blades covered with glass wool slab demonstrated the best noise attenuation characteristics. The reduction of equiv- alent sound pressure level subject to blade inclination angle was from 10.8 to 12.5 dB. Sound pressure level reduction
by louver with blades covered with poly- styrene foam slabs was weaker: the reduction of equivalent sound pressure level was from 5.4 to 8.4 dB. Louver with blades not covered with any acoustic material demonstrated the least noise attenuation result from 1.9 to 3.9 dB
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.