Our results show that sparse coding is an effective way to define spectral features of the cardiac cycle and its sub-cycles for the purpose of classification. In addition, we demonstrate that sparse coding can be combined with additional feature extraction methods to improve classification accuracy.
With the recent COVID-19 pandemic, healthcare systems all over the world are struggling to manage the massive increase in emergency department (ED) visits. This has put an enormous demand on medical professionals. Increased wait times in the ED increases the risk of infection transmission. In this work we present an open-source, low cost, off-body system to assist in the automatic triage of patients in the ED based on widely available hardware. The system initially focuses on two symptoms of the infection -fever and cyanosis. The use of visible and far-infrared cameras allows for rapid assessment at a 1m distance, thus reducing the load on medical staff and lowering the risk of spreading the infection within hospitals. Its utility can be extended to a general clinical setting in non-emergency times as well to reduce wait time, channel the time and effort of healthcare professionals to more critical tasks and also prioritize severe cases.Our system consists of a Raspberry Pi 4, a Google Coral USB accelerator, a Raspberry Pi Camera v2 and a FLIR Lepton 3.5 Radiometry Long-Wave Infrared Camera with an associated IO module. Algorithms running in real-time detect the presence and body parts of individual(s) in view, and segments out the forehead and lip regions using PoseNet. The temperature of the forehead-eye area is estimated from the infrared camera image and cyanosis is assessed from the image of the lips in the visible spectrum. In our preliminary experiments, an accuracy of 97% was achieved for detecting fever and 77% for the detection of cyanosis, with a sensitivity of 91% and area under the receiver operating characteristic curve of 0.91. Heart rate and respiratory effort are also estimated from the visible camera.Although preliminary results are promising, we note that the entire system needs to be optimized before use and assessed for efficacy. The use of low-cost instrumentation will not produce temperature readings and identification of cyanosis that is acceptable in many situations. For this reason, we are releasing the full code stack and system design to allow others to rapidly iterate and improve the system. This may be of particular benefit in low-resource settings, and low-to-middle income countries in particular, which are just beginning to be affected by COVID-19.
We propose a multiple initialization based spectral peak tracking (MISPT) technique for heart rate monitoring from photoplethysmography (PPG) signal. MISPT is applied on the PPG signal after removing the motion artifact using an adaptive noise cancellation filter. MISPT yields several estimates of the heart rate trajectory from the spectrogram of the denoised PPG signal which are finally combined using a novel measure called trajectory strength. Multiple initializations help in correcting erroneous heart rate trajectories unlike the typical SPT which uses only single initialization. Experiments on the PPG data from 12 subjects recorded during intensive physical exercise show that the MISPT based heart rate monitoring indeed yields a better heart rate estimate compared to the SPT with single initialization. On the 12 datasets MISPT results in an average absolute error of 1.11 BPM which is lower than 1.28 BPM obtained by the state-of-the-art online heart rate monitoring algorithm.
BACKGROUND:The retrospective analysis of electroencephalogram (EEG) signals acquired from patients under general anesthesia is crucial in understanding the patient's unconscious brain's state. However, the creation of such database is often tedious and cumbersome and involves human labor. Hence, we developed a Raspberry Pi-based system for archiving EEG signals recorded from patients under anesthesia in operating rooms (ORs) with minimal human involvement. METHODS: Using this system, we archived patient EEG signals from over 500 unique surgeries at the Emory University Orthopaedics and Spine Hospital, Atlanta, for about 18 months. For this, we developed a software package that runs on a Raspberry Pi and archives patient EEG signals from a SedLine Root EEG Monitor (Masimo) to a secure Health Insurance Portability and Accountability Act (HIPAA) compliant cloud storage. The OR number corresponding to each surgery was archived along with the EEG signal to facilitate retrospective EEG analysis. We retrospectively processed the archived EEG signals and performed signal quality checks. We also proposed a formula to compute the proportion of true EEG signal and calculated the corresponding statistics. Further, we curated and interleaved patient medical record information with the corresponding EEG signals. RESULTS:We retrospectively processed the EEG signals to demonstrate a statistically significant negative correlation between the relative alpha power (8-12 Hz) of the EEG signal captured under anesthesia and the patient's age. CONCLUSIONS: Our system is a standalone EEG archiver developed using low cost and readily available hardware. We demonstrated that one could create a large-scale EEG database with minimal human involvement. Moreover, we showed that the captured EEG signal is of good quality for retrospective analysis and combined the EEG signal with the patient medical records. This project's software has been released under an open-source license to enable others to use and contribute. (Anesth Analg 2022;134:380-8) KEY POINTS• Question: Is it possible to automate the process of archiving patient electroencephalogram (EEG) signal from a Sedline Root monitor and interleave patient medical information with the EEG recordings to do retrospective EEG analysis? • Findings: The EEG archiving process can be semiautomated by utilizing a Raspberry Pi-based data archival system, and the patient medical information can be interleaved with the EEG recordings using the operating room (OR) number of the captured EEG records. • Meaning: With this system, we can create large database (>500 patients) of EEG recordings with associated patient medical records with minimal human labor for retrospective analysis.
The non-contact patient monitoring paradigm moves patient care into their homes and enables long-term patient studies. The challenge, however, is to make the system non-intrusive, privacy-preserving, and low-cost. To this end, we describe an open-source edge computing and ambient data capture system, developed using low-cost and readily available hardware. We describe five applications of our ambient data capture system. Namely: (a) Estimating occupancy and human activity phenotyping; (b) Medical equipment alarm classification; (c) Geolocation of humans in a built environment; (d) Ambient light logging; and (e) Ambient temperature and humidity logging. We obtained an accuracy of 94% for estimating occupancy from video. We stress-tested the alarm note classification in the absence and presence of speech and obtained micro averaged F1 scores of 0.98 and 0.93, respectively. The geolocation tracking provided a room-level accuracy of 98.7%. The root mean square error in the temperature sensor validation task was 0.3°C and for the humidity sensor, it was 1% Relative Humidity. The low-cost edge computing system presented here demonstrated the ability to capture and analyze a wide range of activities in a privacy-preserving manner in clinical and home environments and is able to provide key insights into the healthcare practices and patient behaviors.
Rett syndrome, a rare genetic neurodevelopmental disorder in humans, does not have an effective cure. However, multiple therapies and medications exist to treat symptoms and improve patients’ quality of life. As research continues to discover and evaluate new medications for Rett syndrome patients, there remains a lack of objective physiological and motor activity-based (physio-motor) biomarkers that enable the measurement of the effect of these medications on the change in patients’ Rett syndrome severity. In our work, using a commercially available wearable chest patch, we recorded simultaneous electrocardiogram and three-axis acceleration from 20 patients suffering from Rett syndrome along with the corresponding Clinical Global Impression—Severity score, which measures the overall disease severity on a 7-point Likert scale. We derived physio-motor features from these recordings that captured heart rate variability, activity metrics, and the interactions between heart rate and activity. Further, we developed machine learning (ML) models to classify high-severity Rett patients from low-severity Rett patients using the derived physio-motor features. For the best-trained model, we obtained a pooled area under the receiver operating curve equal to 0.92 via a leave-one-out-patient cross-validation approach. Finally, we computed the feature popularity scores for all the trained ML models and identified physio-motor biomarkers for Rett syndrome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.