Pneumatic compression of tissues with lymph stasis is, aside from the manual massage, a commonly used therapeutic modality in limb lymphedema. A number of pneumatic devices have been constructed. There is lack of reports of comparative studies determining inflation pressure levels, inflation/deflation cycle times, and total pumping times. Aim: We tried to answer the question how high compression pressure and how long compression timing should be applied to the limb soft tissues to reach tissue fluid (TF) head pressure above 30 mmHg, necessary to initiate proximal flow. Methods: TF pressures were measured subcutaneously during intermittent pneumatic compression in the lymphedematous limbs stage II to IV. Pressures of 50, 80, and 120 mmHg and timing 5, 20, and 50 sec were applied. Results: a) the TF head pressures were lower than those in inflated chambers, b) inflation time of 5 and 20 sec was not long enough to generate TF head pressures above 30 mmHg, even if the compression pressures were as high as 120 mmHg, c) the 50 sec timing allowed to reach head pressures above 30 mmHg; however, they remained always lower than in the compression chamber, d) TF head pressures differed at various levels of the limb depending on the soft tissue mass, e) deflation of the inflated whole sleeve for 5 and 20 sec was followed by high end pressures, whereas that of 50 sec brought about pressure drop to 0, facilitating refilling with TF of the distal parts of the massaged limb. Conclusions: Our observations point to the necessity of applying high pressures and compression times over 50 sec, to generate effective TF pressures and provide enough time for creating TF flow. Short inflation times generate TF pressures as in one-chamber devices that preclude its effectiveness compared to the multi-chamber devices.
Tissue fluid pressures generated by a pneumatic device were found lower than in the compression chambers. The obtained results point to the necessity of applying high pressures and longer compression times to generate effective tissue fluid pressures and to provide enough time for moving the stagnant fluid.
Background and aimComparison of different irrigation and agitation methods for the removal of two types of calcium hydroxide medicaments from the root canal walls.MethodsFifty extracted single rooted teeth were selected for this study. After decoronation, the root canals of these teeth were prepared to the size F3 (30 no.) using rotary ProTaper file system. These samples were randomly divided into four groups. Group 1 (n=20) were filled completely with water based calcium hydroxide (CH), Group 2 (n=20) were filled with oil based CH using lentulo spiral, Group 3 (n=5) - the positive control group received the CH as intracanal medication, but no subsequent removal, Group 4 (n=5) - the negative control did not receive CH placement. Further on, Group 1 and Group 2 were divided into four sub-groups (n=5). In sub-group A we performed conventional syringe irrigation with side-vented needle sub-group B) manual dynamic agitation, sub-group C sonic agitation using endoactivator, sub-group D passive ultrasonic irrigation (PUI). Roots were split longitudinally into mesial and distal halves. Digital images of the root canal walls were acquired by a Dental Operating Microscope (DOM) and assessed by using a scoring criteria at different thirds (coronal, middle and apical) of the root canal as follows: score 1, score 2, score 3, and score 4. Data were analyzed applying one-way analysis of variance (ANOVA) and Tukey’s multiple comparison tests at a 95% confidence interval (P < 0.05).ResultsStatistically significant differences were not found between the experimental groups and the negative group in any one third of the root canal (P>0.05). However, a difference did exist between the experimental groups and the positive control group (P<0.05). None of the experimental groups totally removed CH substances from root canal walls.ConclusionAmong all experimental groups, removal of CH was best achieved by sonic agitation using endoactivator followed by passive ultrasonic irrigation (PUI), manual dynamic agitation and conventional syringe irrigation with side-vented needle.
AimThe aim of this study was to compare the antimicrobial efficacy of cysteamine, calcium hydroxide[Ca(OH)2], triple antibiotic paste (TAP), chlorhexidine (CHX) and their combinations against Enterococcus faecalis (E. Faecalis).MethodsThe E. Faecalis eradication capacity of cysteamine, Calcium hydroxide (Ca[OH]2), TAP, CHX, and their combinations was tested on E. Faecalis by Kirby Brauer disc diffusion method.ResultsCysteamine in combination with TAP was able to completely eradicate E. Faecalis within 24 hours. Ca(OH)2 was unable to show its effect on E. Faecalis in the given time.ConclusionCysteamine increased the E. Faecalis eradicating capacity of TAP and also showed positive results when used in combination with Ca(OH)2, which if used alone was unable to show any action in 24 hours.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.