Synthesis of a novel pyrene derivative sensor (Py-Met) based on amino acid and its fluorescent behavior for Hg(II) in water was investigated. Upon Hg(II) binding, the Py-Met-bearing sulfonamide group exhibited a considerable excimer emission at 480 nm along with a decrease of monomer emission at 383 nm. Py-Met allows a selective and sensitive ratiometric detection of Hg(II) without any interference from other metal ions.
A pyrene derivative chemosensor (Pyr-WH) based on a dipeptide shows a highly sensitive ratiometric response to Ag(I) as well as silver nanoparticles in aqueous solution at physiological pH. Pyr-WH penetrated live HeLa cells and exhibits a ratiometric response to intracellular Ag(I). The binding mode of Pyr-WH with Ag(I) was characterized based on fluorescence changes in different pH, NMR, and ESI mass spectrometer experiments.
Fluorescent chemosensors (1 and 2, Py-(Arg)nGlyGlyGly(Arg)nLys(Py)-NH2, n = 2 and 3) bearing two pyrene (Py) labeled heparin-binding peptides were synthesized for the sensitive ratiometric detection of heparin. The peptidyl chemosensors (1 and 2) sensitively detected nanomolar concentrations of heparin in aqueous solutions and in serum samples via a ratiometric response. In 100% aqueous solutions at pH 7.4, both chemosensors exhibited significant excimer emission at 486 nm as well as weak monomer emission in the absence of heparin. Upon the addition of heparin into the solution, excimer emission increased with a blue shift (10 nm) and monomer emission at 376 nm decreased. The chemosensors showed a similar sensitive ratiometric response to heparin independent of the concentration of the chemosensors. The peptidyl chemosensors were applied to the ratiometric detection of heparin over a wide range of pH (1.5-11.5) using the excimer/momomer emission changes. In the presence of serum, 1 and 2 displayed significant monomer emission at 376 nm with relatively weak excimer emission and the addition of heparin induced a significant increase in excimer emission at 480 nm and a concomitant decrease in monomer emission. The enhanced ratiometric response to heparin in the serum sample was due to the interactions between the peptidyl chemosensors and serum albumin in the serum sample. The detection limits of 2 for heparin were less than 1 nM in 100% aqueous solutions and serum samples. The peptidyl chemosensors bearing two heparin-binding sites are a suitable tool for the sensitive ratiometric detection of nanomolar concentrations of heparin in 100% aqueous solutions and serum samples.
The FeCl(3) x 6H(2)O-catalyzed Friedel-Crafts arylation reactions of N-sulfonyl aldimines or sulfonamidesulfones with electron-rich arenes and heteroarenes, which lead to the formation of triarylmethanes and bis-heteroarylarylmethanes, are developed. The use of mild reaction conditions, low catalytic loading, high yield, and single step synthesis are the advantages of the present procedure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.