To alleviate the scarcity of clean water, solar steam generation, which utilizes the green and abundant resources of Earth, has attracted considerable attention and been recognized as a sustainable technology to purify seawater and wastewater.
GS inhibits the expression of the ICAM-1 gene in ARPE-19 cell stimulated with TNF-alpha or IFN-gamma through blockade of NF-kappaB subunit p65 and nuclear translocation of STAT1. This study has demonstrated a potentially important property of GS in reducing ICAM-1 mediated inflammatory mechanisms in the eye.
The water drinking test (WDT) was once frequently used as a diagnostic tool for glaucoma, but not so often nowadays. In this study, we investigated the potential use of the WDT on the evaluation of trabeculectomy patency. Twenty age-matched volunteers and thirty-six glaucoma patients who were to receive trabeculectomy procedure were enrolled in this study. The WDT was given to the volunteers once and to all glaucoma patients before undergoing trabeculectomy and at certain intervals after the procedure. The WDT was performed in a standard manner. We defined four parameters after performing the WDT: Initial Pressure [IP, intraocular pressure (IOP) level before the WDT]; Slope of Ascending Trend (SOAT, the slope between baseline IOP and the highest IOP level); Peak Pressure (PP, the highest IOP level during the WDT); and End Pressure (EP, the IOP level after the WDT). It was found that the results of the WDT and trabeculectomy patency were strongly correlated. The four parameters in success and failure cases were significantly different at the last follow up: IP: (15.2 +/- 3.6 vs. 25.3 +/- 6.4, p<0.01); SOAT: (0.9 +/- 0.3 vs. 1.8 +/- 1.2, p<0.01); PP: (19.2 +/- 6.4 vs. 39.5 +/- 12.2, p<0.01); EP: (15.5 +/- 4.8 vs. 29.4 +/- 8.2, p<0.01). Thus, it was observed in this study that WDT was not only easy and safe to perform, but also valuable in evaluating the patency of trabeculectomy.
Two teenaged girls had orthokeratology to correct myopia. The postoperative development of corneal iron rings in both eyes was disclosed by a biomicroscopic examination at 3 months in 1 patient and 5 months in the other. The location of the corneal iron rings coincided with the fitting curve of the reverse-geometry rigid contact lens, suggesting that the rings might have developed from tear pooling.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.