The incidental finding of focal FDG uptake in the bowel justifies further investigation of these foci and should not be dismissed as physiologic uptake. Premalignant lesions, such as adenoma, are often found, and early treatment may prevent the development of carcinoma.
We propose and demonstrate the feasibility of using a highly sensitive microbend multimode fiber optic sensor for simultaneous measurement of breathing rate (BR) and heart rate (HR). The sensing system consists of a transceiver, microbend multimode fiber, and a computer. The transceiver is comprised of an optical transmitter, an optical receiver, and circuits for data communication with the computer via Bluetooth. Comparative experiments conducted between the sensor and predicate commercial physiologic devices showed an accuracy of ±2 bpm for both BR and HR measurement. Our preliminary study of simultaneous measurement of BR and HR in a clinical trial conducted on 11 healthy subjects during magnetic resonance imaging (MRI) also showed very good agreement with measurements obtained from conventional MR-compatible devices.
This paper describes a novel microbend fiber optic sensor system for respiratory monitoring and respiratory gating in the MRI environment. The system enables the noninvasive real-time monitoring and measurement of breathing rate and respiratory/body movement pattern of healthy subjects inside the MRI gantry, and has potential application in respiratory-gated image acquisition based on respiratory cues. The working principle behind this sensor is based on the microbending effect of an optical fiber on light transmission. The sensor system comprises of a 1.0-mm-thin graded-index multimode optical fiber-embedded plastic sensor mat, a photoelectronic transceiver, and a computer with a digital signal processing algorithm. In vitro testing showed that our sensor has a typical signal-to-noise ratio better than 28 dB. Clinical MRI trials conducted on 20 healthy human subjects showed good and comparable breathing rate detection (with an accuracy of ±2 bpm) and respiratory-gated image quality produced using the sensor system, with reference to current predicate hospital device/system. The MRI safe, ease of operation characteristics, low fabrication cost, and extra patient comfort offered by this system suggest its good potential in replacing predicate device/system and serve as a dual function in real-time respiratory monitoring and respiratory-gated image acquisition at the same time during MRI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.