Vancomycin-resistant enterococci (VRE), especially Enterococcus faecium, have been a global concern, often causing serious healthcare-associated infections. We established a rapid approach for detecting E. faecium and vancomycin-resistance genes (vanA and vanB) in clinical samples using isothermal recombinase polymerase amplification (RPA) combined with a lateral-flow (LF) strip. Specific RPA primer sets and probes for ddl (to identify the presence of E. faecium) vanA and vanB genes were designed. The RPA reaction was performed under isothermal condition at 37 °C within 20 min and read using the LF strip within a further 5 min. A total of 141 positive blood-cultures and 136 stool/rectal swab samples were tested using RPA-LF method compared to the conventional PCR method. The RPA-LF method exhibited 100% sensitivity in both blood-culture (60 E. faecium; 35 vanA type and two vanB type) and stool/rectal-swab samples (63 E. faecium and 36 vanA type) without cross-reaction (100% specificity). The lower detection limit of the RPA-LF was approximately 10 times better than that of the conventional PCR method. The RPA-LF method is an alternative rapid method with excellent sensitivity and specificity for detecting E. faecium, vanA, and vanB, and it has the potential to be used as a point-of-care device for VRE therapy and prevention.
Staphylococcus aureus, especially methicillin-resistant S. aureus (MRSA), is an important bacterium that causes community and healthcare-related infections throughout the world. However, the current conventional detection methods are time-consuming. We therefore developed and evaluated a recombinase polymerase amplification-lateral flow strip (RPA-LF) approach for detection of MRSA in positive blood-culture samples. Sixty positive blood-cultures from a hospital were tested directly without DNA extraction and purification before the amplification reaction. RPA primers and probes were designed for nuc (encoding thermonuclease) and mecA (encoding penicillin-binding protein 2a) genes to diagnose S. aureus and its methicillin-resistance status. The RPA reaction occurred under isothermal conditions (45°C) within 20 min and a result was provided by the LF strip in a further 5 min at room temperature. The evaluation of RPA-LF using blood-culture samples showed 93.3% (14/15) sensitivity for identifying S. aureus, and no cross-amplification was seen [100% (45/45) specificity]. For detection of methicillin resistance, the RPA-LF test provided 100% (16/16) sensitivity and 97.7% (43/44) specificity. The RPA-LF is rapid, highly sensitive, robust and easy to use. It can be used for direct detection of MRSA with no requirement for special equipment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.