SummaryIn the staging of lung cancer with positron emission tomography (PET) positive mediastinal lymph nodes, tissue sampling is required. The performance of transbronchial needle aspiration (TBNA) using linear endobronchial ultrasound (real-time EBUS-TBNA) under local anaesthesia and the value of PET for prediction of pathological results were assessed in that setting. The number of eluded surgical procedures was evaluated. All consecutive patients with suspected/proven lung cancers and FDG-PET positive mediastinal adenopathy were included. If no diagnosis was reached, further surgical sampling was required. Lymph node SUVmax (maximum standardized uptake value) was assessed in patients whose PET was performed in the leading centre. One hundred and six patients were included. The average number of TBNA samples per patient was 4.9 ±1.1. The prevalence of lymph node metastasis was 58%. Sensitivity, accuracy and negative predictive value of EBUS-TBNA in the staging of mediastinal hot spots were 95, 97 and 91%. Patients without malignant lymph node involvement showed lower SUVmax (respective median values of 3.7 and 10.0; p < 0.0001 ). Surgical procedures were eluded in 56% of the patients. Real-time EBUS-TBNA should be preferred over mediastinoscopy as the first step procedure in the staging of PET mediastinal hot spots in lung cancer patients. In case of negative EBUS, surgical staging procedure should be undertaken. The addition of SUVmax cut-off may allow further refinement but needs validation.
Positron emission tomography with 18F-fluoro-2-deoxy-D-glucose (FDG-PET) is more accurate than computed tomography for staging of mediastinal (hilar) lymph nodes. In the case of positive findings, tissue sampling of lymph nodes is required. The diagnostic/staging yield of transbronchial needle aspiration (TBNA) following endobronchial ultrasound (EBUS) localisation was assessed in this particular clinical setting. The number of avoided surgical procedures was evaluated.All consecutive patients referred for staging and/or diagnosis of mediastinal FDG-PET positive lesions were included. Data were prospectively collected. TBNA sampling of lymph nodes was performed after EBUS localisation. If no diagnosis was reached, further surgical sampling or adequate follow-up was performed.From January 2003 to June 2004, 33 patients were included. The average number of TBNA samples per patient was 4.2¡1.5. Cytological or histological diagnoses were obtained in 27 (82%) of the patients, of which 78% were obtained after previous EBUS localisation. In 25 (76%) of the 33 patients, surgical staging procedures were suppressed.In conclusion, transbronchial needle aspiration after endobronchial ultrasound localisation should be considered as a primary method of evaluation of lymph nodes positive by positron emission tomography with 18F-fluoro-2-deoxy-D-glucose, and may replace the majority of surgical mediastinal staging/diagnostic procedures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.