Contrast-enhanced MRI is the most sensitive technique for detecting liver nodules. No MR signal intensity pattern characteristic of small HCCs enables differentiation from benign nodules, however. Gadolinium enhancement is the most sensitive and specific characteristic of HCC.
Computed tomography (CT) is one of the most commonly used clinical imaging modalities. There have recently been many reports of novel contrast agents for CT imaging. In particular, the development of gold nanoparticles (AuNP) as CT contrast agents is a topic of intense interest. AuNP have favorable characteristics for this application such as high payloads of contrast generating material, strong X-ray attenuation, excellent biocompatibility, tailorable surface chemistry, and tunable sizes and shapes. However, there have been conflicting reports on the role of AuNP size on their contrast generation for CT. We therefore sought to extensively investigate the AuNP size-CT contrast relationship. In order to do this, we synthesized AuNP with sizes ranging from 4 to 152 nm and capped them with 5 kDa m-PEG. The contrast generation of AuNP of different sizes was investigated with three clinical CT, a spectral photon counting CT (SPCCT) and two micro CT systems. X-ray attenuation was quantified as attenuation rate in Hounsfield units per unit concentration (HU/mM). No statistically significant difference in CT contrast generation was found among different AuNP sizes via phantom imaging with any of the systems tested. Furthermore, in vivo imaging was performed in mice to provide insight into the effect of AuNP size on animal biodistribution at CT dose levels, which has not previously been explored. Both in vivo imaging and ex vivo analysis with inductively coupled plasma optical emission spectroscopy (ICP-OES) indicated that AuNP that are 15 nm or smaller have long blood circulation times, while larger AuNP accumulated in the liver and spleen more rapidly. Therefore, while we observed no AuNP size effect on CT contrast generation, there is a significant effect of size on AuNP diagnostic utility.
CARDIAC IMAGINGC oronary CT angiography (CCTA) is currently recommended for the assessment of many cardiovascular diseases, including coronary artery disease (CAD) evaluation (1). CCTA is particularly important for its high negative predictive value for CAD in a low-and intermediaterisk acute chest pain population, with a high sensitivity and specificity for CAD in a low-and intermediate-risk chronic coronary syndrome population (2-5). This had been made possible by the recent technical evolution of the CT systems and the existence of large-scale validation cohort studies (6,7). However, conventional CCTA still has a limited spatial resolution and soft-tissue contrast, which impairs its diagnostic performance for small arteries (ie, ,2 mm) and high-contrast (eg, stent, calcification) and low-contrast (eg, noncalcified plaque) tasks, and carries the risks of relatively high x-ray dose delivery.Over the past 5 years, photon-counting CT (PCCT) technology has emerged in the field of CT imaging. Compared with conventional CT, this new modality has better spatial resolution and soft-tissue contrast and reduced noise, blooming, and beam-hardening artifacts (8). This is because of new energy-resolving detectors, called photon-counting Background. Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose:To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods:In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method.Results: Fourteen consecutive participants (12 men; mean age, 61 years 6 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs 6 0 versus 349 mAs 6 111 for EID DLCT images (P , .01). Proportions of improvement with PCCT images for quality of calcification, stent, and non...
Purpose To investigate the feasibility of using spectral photon-counting computed tomography (CT) to differentiate between gadolinium-based and nonionic iodine-based contrast material in a colon phantom by using the characteristic k edge of gadolinium. Materials and Methods A custom-made colon phantom was filled with nonionic iodine-based contrast material, and a gadolinium-filled capsule representing a contrast material-enhanced polyp was positioned on the colon wall. The colon phantom was scanned with a preclinical spectral photon-counting CT system to obtain spectral and conventional data. By fully using the multibin spectral information, material decomposition was performed to generate iodine and gadolinium maps. Quantitative measurements were performed within the lumen and polyp to quantitatively determine the absolute content of iodine and gadolinium. Results In a conventional CT section, absorption values of both contrast agents were similar at approximately 110 HU. Contrast material maps clearly differentiated the distributions, with gadolinium solely in the polyp and iodine in the lumen of the colon. Quantitative measurements of contrast material concentrations in the colon and polyp matched well with those of actual prepared mixtures. Conclusion Dual-contrast spectral photon-counting CT colonography with iodine-filled lumen and gadolinium-tagged polyps may enable ready differentiation between polyps and tagged fecal material. RSNA, 2016.
Background and Purpose-Although the ability of MRI to investigate carotid plaque composition is well established, the mechanism and the significance of plaque gadolinium (Gd) enhancement remain unknown. We evaluated clinical and histological significance of Gd enhancement of carotid plaque in patients undergoing endarterectomy for carotid stenosis. Methods-Sixty-nine patients scheduled for a carotid endarterectomy prospectively underwent a 3-T MRI. Carotid plaque enhancement was assessed on T1-weighted images performed before and 5 minutes after Gd injection. Enhancement was recorded according to its localization. Histological analysis was performed of the entire plaque and of the area with matched contrast enhancement on MR images. Results-Gd enhancement was observed in 59% patients. Three types of carotid plaques were identified depending on enhancement location (shoulder region, shoulder and fibrous cap, and central in the plaque). Fibrous cap rupture, intraplaque hemorrhage, and plaque Gd enhancement was significantly more frequent in symptomatic than in asymptomatic patients (P=0.043, P<0.0001, and P=0.034, respectively). After histological analysis, Gd enhancement was significantly associated with vulnerable plaque (American Heart Association VI, P=0.006), neovascularization (P<0.0001), macrophages (P=0.030), and loose fibrosis (P<0.0001). Prevalence of neovessels, macrophages, and loose fibrosis in the area of Gd enhancement was 97%, 87%, and 80%, respectively, and was different depending on the enhancement location in the plaque. Fibrous cap status and composition were different depending on the type of plaque. Conclusions-Gd enhancement of carotid plaque is associated with vulnerable plaque phenotypes and related to an inflammatory process. (Stroke. 2012;43:3023-3028.)
A new prototype spectral photon-counting computed tomography (SPCCT) based on a modified clinical CT system has been developed. SPCCT analysis of the energy composition of the transmitted x-ray spectrum potentially allows simultaneous dual contrast agent imaging, however, this has not yet been demonstrated with such a system. We investigated the feasibility of using this system to distinguish gold nanoparticles (AuNP) and an iodinated contrast agent. The contrast agents and calcium phosphate were imaged in phantoms. Conventional CT, gold K-edge, iodine and water images were produced and demonstrated accurate discrimination and quantification of gold and iodine concentrations in a phantom containing mixtures of the contrast agents. In vivo experiments were performed using New Zealand White rabbits at several times points after injections of AuNP and iodinated contrast agents. We found that the contrast material maps clearly differentiated the distributions of gold and iodine in the tissues allowing quantification of the contrast agents’ concentrations, which matched their expected pharmacokinetics. Furthermore, rapid, repetitive scanning was done, which allowed measurement of contrast agent kinetics with high temporal resolution. In conclusion, a clinical scale, high count rate SPCCT system is able to discriminate gold and iodine contrast media in different organs in vivo.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.