Introduction:
UroLift implants are a novel treatment for the obstructive lower urinary tract symptoms arising from benign prostatic hyperplasia. This case study aimed to assess their effectiveness as fiducial marker (FM) surrogates in prostate image-guided radiotherapy (IGRT).
Method:
Cone-beam CT images from a patient receiving prostate radiation therapy underwent manual alignment using UroLift implants and also prostate soft-tissue matching by five experienced therapeutic radiographers. The match values of both methods were compared using Bland–Altman analysis. All five observers were also asked to score the ease of matching using both approaches.
Results:
The 95% mean level of agreement for the UroLift matches were within a 2-mm threshold in all dimensions. Comparison of UroLift and prostate matches had 95% limit of agreement values of −0·98 to 1·78, −0·58 to 0·49 and −1·83 to 1·04 mm in the vertical, longitudinal and lateral planes, respectively. All of the UroLift matches were rated as ‘very easy’ or ‘possible with little difficulty’ by the five observers.
Conclusion:
A small difference between the CBCT UroLift and CBCT prostate match was found. It has been shown that IGRT to the prostate with the aid of the UroLift system implants and CBCT is feasible and can eliminate the need for FM implants. Wider evaluation in a large cohort is recommended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.