Cardiovascular societies have developed recommendations regarding the management of thoracic aortic diseases. While improvements in treatment have been observed during the past decade in regard to patient selection, thoracic endovascular aortic repair (TEVAR) and associated techniques, and high-volume centralization, the broad expansion of TEVAR has raised considerations about its indications, appropriateness, limitations, and application. The aim of this systematic review was to assess the similarities and differences among current cardiovascular societies’ guidelines for the management of thoracic aortic diseases. The MEDLINE, EMBASE, and Cochrane Central Register of Controlled Trials were searched from January 2009 to May 2020. The initial search identified 990 articles. After exclusion of duplicate or inappropriate articles, the final analysis included 5 articles from cardiovascular societies published between 2010 and 2020. Selected controversial topics were analyzed, including diagnosis, imaging, spinal cord ischemia prevention, and management of the most important thoracic aortic pathologies. The analysis included data concerning the therapeutic approach in acute and chronic type B aortic dissection, penetrating aortic ulcer, intramural hematoma, thoracic aortic aneurysm, and traumatic aortic injury, as well a discussion of inflammatory aneurysms, aortitis, and genetic syndromes. The review presents consistent and controversial recommendations, as well as “gray zone” issues that need further investigation. There was significant overlap and agreement among the 5 societies regarding the management of thoracic aortic diseases. Especially in dissection and aneurysm management, TEVAR has established its role as the treatment of choice. However, robust evidence is still needed in many aspects of the management of thoracic aortic pathologies.
PurposeThe newly designed unibody AFX endograft system for endovascular aortic aneurysm repair is the only graft with anatomical fixation to the aortic bifurcation in comparison to most other grafts that use the infrarenal neck as the main fixation point. The aim of this study was to assess the preliminary results of the AFX stent-graft system used with infrarenal aortic component and compare them with those obtained in patients treated with a well established endograft of the same material and pure infrarenal fixation as the Gore Excluder.Materials and MethodsA retrospective analysis of prospectively collected data from March 2014 to December 2014 identified 10 elective abdominal aortic aneurysm patients treated with the AFX endograft, in comparison to a matched group of 20 patients treated with the Excluder stent-graft. Endpoints included technical and clinical success, freedom from any secondary intervention, any type of endoleak and aneurysm related death.ResultsPrimary technical success was achieved in all patients and no 30-day device related complications or deaths were occurred. The two groups were similar in terms of radiation burden, contrast media, duration of the procedure, post implantation syndrome and in-hospital stay. During a median follow-up period of 23 months (range, 18–26 months) there were no differences in clinical success, freedom from reintervention and aneurysm related death. No type I endoleak was observed in either group. Five of the 6 type II endoleaks (1 in the AFX and 4 in the Excluder group) spontaneously resolved, while in only one patient (Excluder) the endoleak remained without however any change in aneurysm sac diameter (log rank=0.34).ConclusionThe initial experience with the AFX stent graft system is promising, with successful aneurysm exclusion and good short-term results. Further and larger studies are needed to fully evaluate the sort as well as the long-term results.
The development of endovascular techniques has improved abdominal aortic aneurysm (AAA) management over the past 2 decades. Different cardiovascular societies worldwide have recommended the endovascular approach as the standard of care in their currently available guidelines. While endovascular treatment has established its role in daily clinical practice, a new debate has arisen regarding the indications, appropriateness, limitations, and role of open surgery. To inform this debate, the MEDLINE, EMBASE, and Cochrane Central Register of Controlled Trials databases were searched from 2010 to May 2020; the systematic search identified 5 articles published between 2011 and 2020 by 4 cardiovascular societies and the National Institute of Health and Care Excellence (NICE). Four debatable domains were assessed and analyzed: diagnostic methods and screening, preoperative management, indications and treatment modalities, and postoperative follow-up and endoleak management. The review addresses controversial proposals as well as widely accepted recommendations and “gray zone” issues that need to be further investigated and analyzed, such as screening in women, medical management, and follow-up imaging. While the recommendations for AAA management have significant overlap and agreement among international cardiovascular societies, the NICE guidelines diverge regarding the role of open repair in aortic disease, recommending conventional surgery in most elective cases.
Background: Abdominal aortic aneurysm represents a distinct group of vascular lesions, in terms of surveillance and treatment. Screening and follow-up of patients via duplex ultrasound has been well established and proposed by current guidelines. However, serum circulating biomarkers could earn a position in individualized patient surveillance, especially in cases of aggressive AAA growth rates. A systematic review was conducted to assess the correlation of AAA expansion rates with serum circulating biomarkers. Methods: A data search of English medical literature was conducted, using PubMed, EMBASE, and CENTRAL, until 7 March 2021, in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis statement (PRISMA) guidelines. Studies reporting on humans, on abdominal aortic aneurysm growth rates and on serum circulating biomarkers were included. No statistical analysis was conducted. Results: A total of 25 studies with 4753 patients were included. Studies were divided in two broad categories: Those reporting on clinically applicable (8 studies) and those reporting on experimental (17 studies) biomarkers. Twenty-three out of 25 studies used duplex ultrasound (DUS) for following patients. Amongst clinically applicable biomarkers, D-dimers, LDL-C, HDL-C, TC, ApoB, and HbA1c were found to bear the most significant association with AAA growth rates. In terms of the experimental biomarkers, PIIINP, osteopontin, tPA, osteopontin, haptoglobin polymorphisms, insulin-like growth factor I, thioredoxin, neutrophil extracellular traps (NETs), and genetic factors, as polymorphisms and microRNAs were positively correlated with increased AAA expansion rates. Conclusion: In the presence of future robust data, specific serum biomarkers could potentially form the basis of an individualized surveillance strategy of patients presenting with increased AAA growth rates.
Purpose: To compare different anatomical characteristics between intact and ruptured large abdominal aortic aneurysms (rAAA >80 mm) with the goal of refining the process of estimating rupture risk. Materials and Methods: A retrospective study involving 62 male patients with large (>80 mm) aneurysms matched for age and smoking produced a 31-patient elective group with a mean maximum aneurysm diameter of 92±9.7 mm and a 31-patient rAAA group (mean maximum aneurysm diameter 95.7±12 mm). Preoperative computed tomography angiography scans were analyzed with a dedicated workstation, and anatomical characteristics of the aortic neck, iliac arteries, and aneurysm were compared in multivariable regression analyses; the outcomes are given as the odds ratio (OR) with 95% confidence interval (CI). The prognostic utility of several characteristics as predictors of rupture occurrence was examined with receiver operating characteristic (ROC) curves. Results: Anatomical characteristics differing significantly between elective and ruptured aneurysms were the infrarenal aortic neck diameters at 5 mm, 10 mm and 15 mm; the neck length and calcification; the common iliac artery (CIA) lengths; the iliac artery indexes; the left CIA and external iliac artery diameters; and the total and true lumen aneurysm volumes. Intraluminal thrombus (ILT) volume did not differ (p=0.76), although its distribution in elective vs ruptured cases did [absent: 0% vs 19%, respectively (p=0.025); circumferential: 61% vs 35%, respectively (p=0.04)]. Total aneurysm volume was higher in rAAA (442±140 mL) vs intact AAA (331±143 mL, p=0.014), while the ILT/total aneurysm volume rate was lower in rAAA (55%) vs intact AAA (70%, p=0.02). Multivariate analysis determined that a shorter left CIA (OR 1.07, 95% CI 1.01 to 1.1, p=0.016) and a smaller total aneurysm volume (OR 1.007, CI. 1.001 to 1.014, p=0.016) were associated with intact AAA. After a ROC curve analysis, left CIA length <50 mm demonstrated a lower incidence of rupture (sensitivity 60% and specificity 78%), while total aneurysm volume <380 mL had 60% sensitivity and specificity. Conclusion: Large rAAAs seem to have different anatomical characteristics than similarly sized intact AAAs. Large intact AAAs have lower total aneurysm volumes and shorter left CIAs, with higher ILT/aneurysm volume rates.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.