A micellar electrokinetic chromatography method for the determination of indomethacin impurities (4-chlorobenzoic acid, 5-methoxy-2-methyl-3-indoleacetic acid, and 3,4-dichloroindomethacin) has been developed. A 64.5/56-cm fused silica 50 μm id capillary with extended light path (150 μm id) detection window was used. Internal standard was 1-naphthylacetic acid. The analytes were separated at 30 kV with DAD detection at 224 nm. A central composite face-centered design was applied for the optimization of the separation conditions. The effect of SDS concentration, content of methanol, concentration of phosphate buffer, and pH of the buffer were studied at three levels. The optimized background electrolyte was 20 mmol/L phosphate buffer (pH 7.57) containing 58 mmol/L SDS and 0% MeOH. Sufficient resolution of all compounds with Rs ≥ 3.5 was achieved within 10 min. The method was validated for a range of 1.25-80 μg/mL of each impurity corresponding to 0.05-3.2% relative to the concentration of indomethacin (2.5 mg/mL). The calibration curves were rectilinear with correlation coefficients r exceeding 0.9994. The lower limit of quantification was 0.05% or 1.25 μg/mL that complies with the reporting limits regarding the ICH Q3A guideline. The method was applied to purity assay of indomethacin in both bulk drug and gel.
CE method for the baseline separation of structurally similar flavonolignans silybin A, silybin B, isosilybin A, isosilybin B, silychristin, silydianin, and their precursor taxifolin in silymarin complex has been developed and validated. The optimized background electrolyte was 100 mmol/L boric acid (pH 9.0) containing 5 mmol/L heptakis(2,3,6-tri-O-methyl)-β-CD and 10% (v/v) of methanol. The separation was carried out in an 80.5/72 cm (50 μm id) fused silica capillary at +25 kV with UV detection at 200 nm. Genistein (10 μg/mL) was used as internal standard. The resolution between the diastereomers of silybin and isosilybin was 1.73 and 2.59, respectively. The method was validated for each analyte in a concentration range of 2.5-50 μg/mL. The calibration curves were rectilinear with correlation coefficients ≥0.9972. The method was applied to determine flavonolignans in two dietary supplements containing Silybum marianum extract. The accuracy was evaluated by comparing the results of the CE analyses of the dietary supplements with those of the reference United States Pharmacopeial HPLC method. The unpaired t-test did not show a statistically significant difference between the results of both the proposed CE and the reference method (p > 0.05, n = 3).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.