Internal tocodynamometry during induced or augmented labor, as compared with external monitoring, did not significantly reduce the rate of operative deliveries or of adverse neonatal outcomes. (Current Controlled Trials number, ISRCTN13667534; Netherlands Trial number, NTR285.)
Vessel-sealing devices may be considered safe and their use may reduce costs due to reduced blood loss and shorter operating time in some abdominal surgical procedures compared to mono- or bipolar electrothermal devices. Wider-ranging RCTs of sufficient quality that assess (cost) effectiveness are required to make firm conclusions.
Incomplete learning curve, insufficient applied technique such as coagulation of the uterine artery without the use of a uterine manipulator, and/or from the contralateral side and/or without previously performed ureterolysis in case of distorted anatomy may be considered as the main predisposing factors.
BackgroundIt has been hypothesized that internal tocodynamometry, as compared with external monitoring, may provide a more accurate assessment of contractions and thus improve the ability to adjust the dose of oxytocin effectively, resulting in fewer operative deliveries and less fetal distress. However, few data are available to test this hypothesis.
MethodsWe performed a randomized, controlled trial in six hospitals in the Netherlands to compare internal tocodynamometry with external monitoring of uterine activity in women for whom induced or augmented labor was required. The primary outcome was the rate of operative deliveries, including both cesarean sections and instrumented vaginal deliveries. Secondary outcomes included the use of antibiotics during labor, time from randomization to delivery, and adverse neonatal outcomes (defined as any of the following: an Apgar score at 5 minutes of less than 7, umbilical-artery pH of less than 7.05, and neonatal hospital stay of longer than 48 hours).
ResultsWe randomly assigned 1456 women to either internal tocodynamometry (734) or external monitoring (722). The operative-delivery rate was 31.3% in the internaltocodynamometry group and 29.6% in the external-monitoring group (relative risk with internal monitoring, 1.1; 95% confidence interval [CI], 0.91 to 1.2). Secondary outcomes did not differ significantly between the two groups. The rate of adverse neonatal outcomes was 14.3% with internal monitoring and 15.0% with external monitoring (relative risk, 0.95; 95% CI, 0.74 to 1.2). No serious adverse events associated with use of the intrauterine pressure catheter were reported.
ConclusionsInternal tocodynamometry during induced or augmented labor, as compared with external monitoring, did not significantly reduce the rate of operative deliveries or of adverse neonatal outcomes. (Current Controlled Trials number, ISRCTN13667534; Netherlands Trial number, NTR285.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.