In this Section, we review the applications of mass spectrometry for the analysis and purification of new chemical entities (NCEs) for pharmaceutical discovery. Since the speed of synthesis of NCEs has dramatically increased over the last few years, new high throughput analytical techniques have been developed to keep pace with the synthetic developments. In this Section, we review both novel, as well as modifications of commonly used mass spectrometry techniques that have helped increase the speed of the analytical process. Part of the review is devoted to the purification of NCEs, which has undergone significant development in recent years, and the close integral association between characterization and purification to drive high throughput operations. At the end of the Section, we review potential future directions based on promising and exciting new developments.
LC/MS is being used for the routine analysis of small molecules in both the discovery and development stages within the pharmaceutical industry. In drug discovery, LC/MS is relied upon to confirm the identity and assess the purity of chemical entities. To ensure the quality of LC/MS analysis, it is important that the LC/MS system is operating within defined performance criteria. Performance monitoring of the system with a standard compound mix offers many advantages over other alternatives, since it monitors the LC/MS system as an integrated unit under the same working conditions as those used for the analysis of samples. It is also a convenient approach, because the test mix can be injected as part of the automated sequence. Use of a test mix for similar purposes has been described previously (Tang, L.; Fitch, W. L.; Alexander, M. S.; Dolan, J. W. Anal. Chem. 2000, 72, 5211-5218). To monitor the performance of ArQule's LC/MS operation (with UV and ELS detection) in greater detail, a set of eight compounds was selected from a collection of 137 commercially available "druglike" compounds. The compounds are generally stable and compliant with the rule-of-five criteria. This enhanced mix has a balanced selection of pKa values and covers the typical range of hydrophobicity and molecular masses of pharmaceutical compounds. Moreover, the selected compounds can generally be ionized using ESI and APCI modes with positive and negative polarity. The test mix can be used under formic acid or ammonium hydroxide conditions and with methanol or acetonitrile as an organic modifier. Performance monitoring with the enhanced mix is demonstrated with respect to ionization and mass measurement, as well as changes in gradient profile, flow rate, buffer pH, and ionic strength.
On-column solvent exchange, using many of the principles of solid-phase extraction, has been implemented to significantly reduce evaporation cycle time following reverse-phase preparative HPLC. Additional benefits, such as a reduced potential for salt formation, thermal decomposition, and residual solvent, are also described. Fractions obtained from preparative separations, typically in a large volume of acetonitrile:water, are injected into the preparative HPLC and then eluted in acetonitrile, creating a new fraction in a volatile organic solvent. Minimal modification to the instrument was required, and unattended operation is possible. Acetonitrile evaporation is achieved within 3 h, compared with 17 h for aqueous-based fractions; lower temperatures can be used during the evaporation step; mobile-phase additives, likely to form salts with the target compound if concentrated in the fraction, are removed before evaporation; sample recovery and purity are unaffected.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.