P, Drewes AM, Gregersen H. The functional lumen imaging probe (FLIP) for evaluation of the esophagogastric junction. Am J Physiol Gastrointest Liver Physiol 292: G377-G384, 2007. First published August 31, 2006; doi:10.1152/ajpgi.00311.2006.-There is a need for new methods to study the dynamics of the esophagogastric junction (EGJ). The aims were to verify the efficacy and usefulness of a "functional lumen imaging probe" (FLIP) for the evaluation of the EGJ. Eight healthy volunteers (6 men), median age 26 (21-35) yr, and two achalasia patients underwent the FLIP procedure. The EGJ was located by manometry. The FLIP measured eight cross-sectional areas (CSAs) 4 mm apart together with the pressure inside a saline-filled cylindrical bag. The data showed the geometric profile of the EGJ reconstructed in a video animation of its dynamic activity. A plot of curve-fitted data for the smallest CSA vs. pressure after balloon distension indicated that the pressure increased from 18 cmH 2O at a CSA of 38 mm 2 to a pressure of 37 cmH2O at a CSA of 230 mm 2 for the healthy controls. In one achalasia patient (unsuccessfully treated with dilations), the CSA never rose above the minimal measurable value despite the pressure increasing to 50 cmH2O. In another achalasia patient (successfully treated with dilations), the pressure only reached 15 cmH2O despite opening to a CSA of 250 mm 2 . In conclusion, FLIP represents the first dynamic technique to profile the function and anatomy of the EGJ. The method can be used practically to evaluate difficult cases of EGJ dysfunction and may provide a role in evaluating patients before and after therapies for diseases affecting the EGJ such as achalasia and gastroesophageal reflux disease. esophagus; competence; distensibility; cross-sectional area; functional imaging THE LOWER ESOPHAGEAL SPHINCTER (LES) is not solely responsible for impeding the flow between the esophagus and the stomach. The crural diaphragm encircles ϳ2 cm of the esophagogastric junction (EGJ), and the sling or oblique fibers of the stomach also contribute to the mechanism (15, 21). Esophageal and gastric motility, pressures in the abdominal and thoracic cavities, and the exact location of the EGJ all play a role in defining its function. The anatomy and behavior of the EGJ also change with time and body posture (20). The EGJ is a very dynamic mechanical structure. A lot of knowledge about the anatomy of the EGJ has been assembled over the last 40 years, but much of our limited understanding of the behavior has been related to manometric studies. Intraluminal pressure recording is the current gold standard for determining the motility characteristics of the esophagus. Although manometry provides useful information on the location of the EGJ and on phasic motility within the lumens of the digestive tract, it may be more restrictive in what it can tell us about sphincteric regions and their dynamics.Two classic diseases involving the EGJ are gastroesophageal reflux disease (GERD) and achalasia. Achalasia is an esophageal ...
No quantitative method has been implemented routinely in clinical practice to assess the oesophago-gastric junction (OGJ). Using impedance planimetry a functional lumen imaging probe (FLIP) was constructed to measure eight cross-sectional areas (CSA) at 4 mm intervals inside a saline-filled bag. To validate the FLIP technique for profiling the OGJ, polymethylmethacrylate (Perspex) cylinders with different CSAs were measured ten times by the FLIP to assess reproducibility and accuracy. A geometric sphincter phantom was constructed and its geometry was measured with a 360 degrees radial ultrasound (US) mini-probe pulled through it at a rate of 1 mm s(-1). The measurements were compared with FLIP measurements. Safety and technique reproducibility were tested on a volunteer. Reproducibility and accuracy between the ten samples were good. The probe performed well with and without a balloon mounted on it except for the smallest CSA (38.5 mm(2)) where there was a difference of 22% from the actual value at one CSA measurement point. The FLIP imaged the phantom geometry as well as the radial scanning US mini-probe. Pilot studies on a volunteer showed that the probe could be placed in the OGJ and the balloon distensions revealed the geometry of the sphincter at various levels of distension. The technique may be useful in accessing the role of the OGJ in diseases such as gastroesophageal reflux disease (GORD) and achalasia and their treatments with surgical and endoscopic therapies.
This nonsystematic review aims to describe recent developments in the use of functional lumen imaging in the gastrointestinal tract stimulated by the introduction of the functional lumen imaging probe. When ingested food in liquid and solid form is transported along the gastrointestinal tract, sphincters provide an important role in the flow and control of these contents. Inadequate function of sphincters is the basis of many gastrointestinal diseases. Despite this, traditional methods of sphincter diagnosis and measurement such as fluoroscopy, manometry, and the barostat are limited in what they can tell us. It has long been thought that measurement of sphincter function through resistance to distension is a better approach, now more commonly known as distensibility testing. The functional lumen imaging probe is the first medical measurement device that purports in a practical way to provide geometric profiling and measurement of distensibility in sphincters. With use of impedance planimetry, an axial series of cross-sectional areas and pressure in a cathetermounted allantoid bag are used for the calculation of distensibility parameters. The technique has been trialed in many valvular areas of the gastrointestinal tract, including the upper esophageal sphincter, the esophagogastric junction, and the anorectal region. It has shown potential in the biomechanical assessment of sphincter function and characterization of swallowing disorders, gastroesophageal reflux disease, eosinophilic esophagitis, achalasia, and fecal incontinence. From this early work, the functional lumen imaging technique has the potential to contribute to a better and more physiological understanding of narrowing regions in the gastrointestinal tract in general and sphincters in particular.
This study aimed to characterize the effect of mechanical stimuli on mesenteric afferent nerve signaling in the isolated rat jejunum in vitro. This was done to determine the effect of mechanical stresses and strains relative to nonmechanical parameters (neurogenic adaptation). Mechanical stimulations were applied to a segment of jejunum from 15 rats using ramp distension with water at three rates of distension, a relaxation test (volume maintained constant from initial pressure of 20 or 40 mmHg), and a creep test (pressure maintained constant). Circumferential stress and strain and the spike rate increase ratio were calculated for evaluation of afferent nerve activity during the mechanical stimulations. Ramp distension evoked two distinct phases of afferent nerve signaling as a function of circumferential stress or strain. Changing the volume distension rate did not change the stress-strain relationship, but faster distension rate increased the afferent firing rate (P Ͻ 0.05). In the stress relaxation test, the spike rate declined faster and to a greater extent than the stress. In the creep test, the spike rate declined, despite a small increase in the strain. Three classes of mechanosensitive singleafferent units (low, wide dynamic range, and high threshold units) showed different response profiles against stress and strain. Lowthreshold units exhibited a near linear relationship against the strain (R 2 ϭ 0.8095), whereas high-threshold units exhibited a linear profile against the stress (R 2 ϭ 0.9642). The afferent response is sensitive to the distension speed and to the stress and strain level during distension. However, the afferent nerve response is not a simple function of either stress or strain. Nonmechanical time-dependent adaptive responses other than those related to viscoelasticity also play a role.
The probe will in future studies be tested for diagnostic purposes related to sphincter of Oddi diseases.
Introduction. Electrical stimulation is used in experimental human pain models. The aim was to develop a model that visualizes the distribution of electrical field in the esophagus close to ring and patch electrodes mounted on an esophageal catheter and to explain the obtained sensory responses. Methods. Electrical field distribution in esophageal layers (mucosa, muscle layers, and surrounding tissue) was computed using a finite element model based on a 3D model. Each layer was assigned different electrical properties. An electrical field exceeding 20 V/m was considered to activate the esophageal afferents. Results. The model output showed homogeneous and symmetrical field surrounding ring electrodes compared to a saddle-shaped field around patch electrodes. Increasing interelectrode distance enlarged the electrical field in muscle layer. Conclusion. Ring electrodes with 10 mm interelectrode distance seem optimal for future catheter designs. Though the model needs further validation, the results seem useful for electrode designs and understanding of electrical stimulation patterns.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.