These evidence-based data indicated that each evaluated exercise, except for downhill walking, has a specific therapeutic value in physical therapy for dogs.
Background
Physical literacy (PL), given as a multidimensional construct, is considered a person’s capacity and commitment to a physically active lifestyle. We investigated the effect of a holistic physical exercise training on PL among physically inactive adults.
Methods
A non-randomised controlled study was conducted. Thirty-one physically inactive adults in the intervention group (IG; 81% females, 44 ± 16 years) participated in a holistic physical exercise training intervention once weekly for 15 weeks. A matched, non-exercising control group (CG) consisted of 30 physically inactive adults (80% female, 45 ± 11 years). PL, compliance and sociodemographic parameters were measured. PL was evaluated by a questionnaire, covering five domains: physical activity behaviour, attitude towards a physically active lifestyle, exercise motivation, knowledge and self-confidence/self-efficacy. Data were analysed using ANCOVA models, adjusted for age, gender and BMI at baseline.
Results
At post-training intervention, the IG showed significant improvements in PL (
p
= 0.001) and in the domains physical activity behaviour (
p
= 0.02) and exercise self-confidence/self-efficacy (p = 0.001), with no changes overserved for the CG regarding PL and those domains. No intervention effect were found for the other three domains, i.e. attitude, knowledge and motivation. Additionally, for the IG baseline BMI was identified to be positively correlated with physical exercise-induced improvements in PL (β = 0.51,
p
= 0.01).
Conclusions
The results from this study are very useful for further public health activities, which aim at helping physically inactive adults to adopt a physically active lifestyle as well as for the development of further PL intervention strategies. This pilot-study was a first attempt to measure PL in inactive adults. Yet, a validated measurement tool is still not available. Further research is necessary to determine the psychometric properties for this PL questionnaire.
Trial registration
German Clinical Trials Register (DRKS),
DRKS00013991
, date of registration: 09.02.2018, retrospectively registered.
Electronic supplementary material
The online version of this article (10.1186/s12889-019-6719-z) contains supplementary material, which is available to authorized users.
The muscles investigated were significantly affected by hip OA. This finding suggests that there is a more distinct resting phase of the muscles during swing and a higher activity during early stance.
A 25% reduction in usual IDeg dose around regular exercise led to more time spent in euglycaemia, with small effects on time spent in hypo- and hyperglycaemia.
Aims To evaluate the sensor performance of the FreeStyle Libre intermittently viewed continuous glucose monitoring system using reference blood glucose levels during moderate-intensity exercise while on either full or reduced basal insulin dose in people with Type 1 diabetes. Methods Ten participants with Type 1 diabetes [four women, mean AE SD age 31.4 AE 9.0 years, BMI 25.5AE3.8 kg/m 2 , HbA 1c 55AE7 mmol/mol (7.2AE0.6%)] exercised on a cycle ergometer for 55 min at a moderate intensity for 5 consecutive days at the clinical research facility, while receiving either their usual or a 75% basal insulin dose. After a 4-week washout period, participants performed the second exercise period having switched to the alternative basal insulin dose. During exercise, reference capillary blood glucose values were analysed using the fully enzymatic-amperometric method and compared with the interstitial glucose values obtained. Intermittently viewed continuous glucose monitoring accuracy was analysed according to median (interquartile range) absolute relative difference, and Clarke error grid and Bland-Altman analysis for overall glucose levels during exercise, stratified by glycaemic range and basal insulin dosing scheme (P<0.05).Results A total of 845 glucose values were available during exercise to evaluate intermittently viewed continuous glucose monitoring sensor performance. The median (interquartile range) absolute relative difference between the reference values and those obtained by the sensor across the glycaemic range overall was 22 (13.9-29.7)%, and was 36.3 (24.2-45.2)% during hypoglycaemia, 22.8 (14.6-30.6)% during euglycaemia and 15.4 (9-21)% during hyperglycaemia. Usual basal insulin dose was associated with a worse sensor performance during exercise compared with the reduced (75%) basal insulin dose [median (interquartile range) absolute relative difference: 23.7 (17.2-30.7)% vs 20.5 (12-28.1)%; P<0.001).Conclusions The intermittently viewed continuous glucose monitoring sensor showed diminished accuracy during exercise. Absolute glucose readings derived from the sensor should be used cautiously and need confirmation by additional finger-prick blood glucose measurements.
Background: E-point-to-septal-separation (EPSS) and the sphericity index (SI) are echocardiographic parameters that are recommended in the ESVC-DCM guidelines. However, SI cutoff values to diagnose dilated cardiomyopathy (DCM) have never been evaluated.Objectives: To establish reference ranges, calculate cutoff values, and assess the clinical value of SI and EPSS to diagnose DCM in Doberman Pinschers.Animals: One hundred seventy-nine client-owned Doberman Pinschers. Methods: Three groups were formed in this prospective longitudinal study according to established Holter and echocardiographic criteria using the Simpson method of disk (SMOD): control group (97 dogs), DCM with echocardiographic changes (75 dogs) and "last normal" group (n = 7), which included dogs that developed DCM within 1.5 years, but were still normal at this time point. In a substudy, dogs with early DCM based upon SMOD values above the reference range but still normal M-Mode measurements were selected, to evaluate if EPSS or SI were abnormal using the established cutoff values.Results: ROC-curve analysis determined <1.65 for the SI (sensitivity 86.8%; specificity 87.6%) and >6.5 mm for EPSS (sensitivity 100%; specificity 99.0%) as optimal cutoff values to diagnose DCM. Both parameters were significantly different between the control group and the DCM group (P < 0.001), but were not abnormal in the "last normal" group. In the substudy, EPSS was abnormal in 13/13 dogs and SI in 2/13 dogs.Conclusions and Clinical Importance: E-point-to-septal-separation is a valuable additional parameter for the diagnosis of DCM, which can enhance diagnostic capabilities of M-Mode and which performs similar as well as SMOD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.