When given by computer-controlled infusion during spinal anesthesia for cesarean delivery, norepinephrine was effective for maintaining blood pressure and was associated with greater heart rate and cardiac output compared with phenylephrine. Further work would be of interest to confirm the safety and efficacy of norepinephrine as a vasopressor in obstetric patients.
Refusal of admission to our ICU is common. Excess mortality of patients refused is most marked in the middle range of severity of illness. Age, diagnostic group, and severity of illness are important in decision making. Strategies should be developed to create admission criteria that would identify patients in the middle range of severity of illness who should benefit most from ICU care.
Ephedrine crosses the placenta to a greater extent and undergoes less early metabolism and/or redistribution in the fetus compared with phenylephrine. The associated increased fetal concentrations of lactate, glucose, and catecholamines support the hypothesis that depression of fetal pH and base excess with ephedrine is related to metabolic effects secondary to stimulation of fetal beta-adrenergic receptors. Despite historical evidence suggesting uteroplacental blood flow may be better maintained with ephedrine, the overall effect of the vasopressors on fetal oxygen supply and demand balance may favor phenylephrine.
We used an in vitro model of continuous venovenous hemofiltration (CVVH) to characterize amikacin adsorption by polyacrylonitrile (PAN) and polyamide filters. A blood-crystalloid mixture dosed with amikacin was pumped from a reservoir through a hemofiltration circuit and back to the reservoir. All ultrafiltrate was also returned to the reservoir. The level of adsorption was calculated from the fall in the amikacin concentration. The dose and the initial concentration of amikacin were varied, as were the pH, the type of hemofilter, and the hemofilter surface area. The reversibility of adsorption and the effect of repeated dosing were also studied. The level of adsorption by 0.6-m 2 PAN filters was significantly greater than that by 0.6-m 2 polyamide filters. Adsorption was increased by increasing the dose of amikacin even when the initial concentration was unchanged. It was unaffected by the pH (pH 6.8 or 7.4) or the hemofilter surface area (0.6 m 2 or 0.9 m 2 ). Repeated doses of amikacin resulted in further adsorption. In a saturation experiment, the maximum adsorptive capacity of 0.6-m 2 PAN hemofilters was at least 546.9 mg (range, 427.6 to 577.5 mg). The adsorption of amikacin by hemofilters is irreversible and was associated with the dose and the hemofilter material but not the hemofilter surface area. Close monitoring of peak amikacin levels should be considered for patients receiving CVVH with PAN hemofilters.
Impaired long-axis motion is a sensitive marker of systolic myocardial dysfunction, but no data are available that relate long-axis changes in systole with those in diastole, particularly in subjects with diastolic dysfunction and a 'normal' left ventricular (LV) ejection fraction. A total of 311 subjects (including 105 normal healthy volunteers) aged 20-89 years with variable degrees of systolic function (LV ejection fraction range 0.15-0.84) and diastolic function were studied using tissue Doppler echocardiography and M-mode echocardiography to determine mean mitral annular amplitude and peak velocity in systole and early and late diastole. The LV systolic mitral annular amplitude (S(LAX), where LAX is long-axis amplitude) and peak velocity (S(m)) correlated well with the respective early diastolic components (E(LAX) and E(m)) and late diastolic (atrial) components (A(LAX) and A(m)). A non-linear equation fitted better than a linear relationship (non-linear model: S(LAX) against E(LAX), r(2)=0.67; S(m) against E(m), r(2)=0.60; S(LAX) against A(LAX) and S(m) against A(m), r(2)=0.42). After adjusting for age, sex and heart rate, linear relationships of early diastolic (E(LAX), r(2)=0.70; E(m), r(2)=0.60) and late diastolic (A(LAX), r(2)=0.61; A(m), r(2)=0.64) long-axis amplitudes and velocities with the respective values for S(LAX) and S(m) were found, even in those subjects with apparently 'isolated' diastolic dysfunction. Long-axis changes in systole or diastole did not correlate with Doppler mitral velocities. We conclude that ventricular long-axis changes in early diastole are closely related to systolic function, even in subjects with diastolic dysfunction. 'Pure' or isolated diastolic dysfunction is uncommon.
The aim of this study was to characterize vancomycin adsorption by polyacrylonitrile (PAN), polyamide, and polysulfone hemofilters using an in vitro model of hemofiltration. Vancomycin (36 mg) was added to a blood-crystalloid mixture of known volume (target concentration of 50 mg/L) and pumped around a closed circuit. Adsorption, which was calculated from the fall in concentration over 120 min, was significantly greater by 0.6-m(2) PAN filters (10.08 +/- 2.26 mg) than by 0.6-m(2) polyamide (5.20 +/- 1.82 mg) or 0.7-m(2) polysulfone (4.80 +/- 2.40 mg) filters (P < 0.05). Cumulative adsorption was not changed by the addition of 500-mL lactated Ringer's solution (to reduce the circulating vancomycin concentration). These data show that although adsorption of vancomycin by PAN, polyamide, and polysulfone hemofilters occurs, the absolute adsorption is small. Adsorption is dependent on filter material and is not reversed by a decrease in circulating concentration.
Plasma adrenaline and noradrenaline concentrations were measured in 10 consecutive patients during functional endoscopic sinus surgery (FESS). Surgery was preceded by nasal packing with 5 ml 2% cocaine solution, followed by infiltration with 1:80,000 adrenaline and 2% lignocaine. All patients showed a marked rise in plasma adrenaline concentration within 4 min of commencing infiltration, which was not related to the patient's sex, age, weight, the total amount injected, nor the amount injected into the nose. Surgeons should be aware of this marked, but unpredictable, systemic absorption of locally infiltrated vasoconstrictors. Pulse and ECG monitoring should be considered mandatory for such procedures, even when surgery is performed under local anaesthesia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.