A 74-yr-old man with two prior coronary bypass surgeries experienced perforation of an occluded aortocoronary vein graft during a transluminal extraction catheter (TEC) procedure for unstable angina. The perforation was successfully closed using a Palmaz 154 stent covered with a short segment of autologous antecubital vein. c 19% Wllny-LImm. inc
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.