Purpose. To investigate the clinical outcomes and possible risk factors associated with rotational stability after the implantation of a V4c toric implantable Collamer lens (TICL) for the correction of moderate to high myopic astigmatism. Methods. A total of 112 eyes of 66 patients with moderate to high myopic astigmatism underwent TICL implantation. All patients were followed up for more than 1 year. The uncorrected and best-corrected visual acuity (UCVA and BCVA), astigmatism and spherical equivalent, intraocular pressure, vault, endothelial cell morphometry, and rotation of the TICL axis were assessed at l day, 1 week, 1 month, 3 months, 6 months, and 12 months postoperatively. Postoperative rotation was defined as the angle between the intended axis and the achieved axis. Regression analysis was used to investigate the possible risk factors for TICL rotation postoperatively. Results. The mean efficacy index and safety index 12 months postoperatively were 1.03 ± 0.09 and 1.05 ± 0.10, respectively. All patients had the same or better visual acuity than preoperatively. The mean astigmatism value decreased from −1.86 ± 0.79 D preoperatively to −0.37 ± 0.35 D. The mean absolute axis deviation of the TICL at the last follow-up was 2.75 ± 2.04° (range, 0°∼11°). The mean manifest refraction spherical equivalent (MRSE) changed from -9.04 ± 2.67 D preoperatively to −0.67 ± 0.51 D postoperatively. The logistic regression demonstrated that the absolute degree of TICL rotation had a significant association with the fixation angle of the TICL and the size of the lens ( P = 0.003 , P = 0.026 , resp.). Conclusion. The results of our study support that TICL implantation is safe, effective, and predictable in the treatment of moderate to high myopic astigmatism, with relatively good postoperative rotational stability.
Research in the field of wearable triboelectric generators is increasing, and pioneering research into real applications of this technology is a growing need in both scientific and industry research. In addition to the two key characteristics of wearable triboelectric generators of flexibility and generating friction, features such as softness, breathability, washability, and wear resistance have also attracted a lot of attention from the research community. This paper reviews wearable triboelectric generators that are used in human clothing for energy conversion. The study focuses on analyzing fabric structure and examining the integration method of flexible generators and common fibers/yarns/textiles. Compared to the knitting method, the woven method has fewer restrictions on the flexibility and thickness of the yarn. Remaining challenges and perspectives are also investigated to suggest how to bring fully generated clothing to practical applications in the near future.
AIM: To investigate changes in macular vessels and thickness in myopic eyes after intraocular collamer lens (ICL) implantation using quantitative optical coherence tomography angiography (OCTA). METHODS: This retrospective included 73 myopic eyes of 73 patients (average age, 27.53±6.16y) who underwent ICL implantation (28 eyes were Toric ICL). Axial length (AL), uncorrected visual acuity (UCVA), refractive dioptre (RD), intraocular pressure (IOP) and OCTA were measured and compared with before and 1wk, 1, and 3mo after surgery. OCTA was used to image vessel density (VD) and skeleton density (SD) in both the superficial (SCP) and deep capillary plexus (DCP). Central retinal thickness (CRT) and ganglion cell-inner plexiform layer thickness (GCT) were also measured. Changes between pre- and postoperative measurements were analysed by repeated measures analysis of variance. RESULTS: Compared with preoperative data, postoperative data on UCVA revealed significant improvements in all patients (P<0.05). However, there was no significant difference in IOP. After the operation, CRT and GCT exhibited significant changes (P<0.05). Among these measures, CRT was significantly higher at one and three months postoperative (all P<0.01). GCT was significantly higher at 1wk, 1, and 3mo postoperative (all P<0.01). Changes in VD and SD were nonsignificant in both the SCP and DCP. There was no difference in postoperative changes between the ICL and Toric ICL groups. CONCLUSION: ICL and Toric ICL implantation both have good efficacy and safety for myopic eyes, but macular area changes that occur after surgery need attention.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.