Parkinson’s disease (PD) is the second most common neurodegenerative disease in the United States after Alzheimer’s disease (AD). To help understand the electrophysiology of these diseases, N27 neuronal cells have been used as an in vitro model. In this study, a flexible graphene-based biosensor design is presented. Biocompatible graphene was manufactured using a liquid-phase exfoliation method and bovine serum albumin (BSA) for further exfoliation. Raman spectroscopy results indicated that the graphene produced was indeed few-layer graphene (FLG) with ID/IGGraphene= 0.11. Inkjet printing of this few-layer graphene ink onto Kapton polyimide (PI) followed by characterization via scanning electron microscopy (SEM) showed an average width of ≈868 µm with a normal thickness of ≈5.20 µm. Neuronal cells were placed on a thermally annealed 3D printed graphene chip. A live–dead cell assay was performed to prove the biosensor biocompatibility. A cell viability of approximately 80% was observed over 96 h, which indicates that annealed graphene on Kapton PI substrate could be used as a neuronal cell biosensor. This research will help us move forward with the study of N27 cell electrophysiology and electrical signaling.
Presented here is a scalable and aqueous phase exfoliation of graphite to high yield and quality of few layer graphene (FLG) using Bovine Serum Albomine (BSA) and wet ball milling. The produced graphene ink is tailored for printable and flexible electronics, having shown promising results in terms of electrical conductivity and temporal stability. Shear force generated by steel balls which resulted in 2–3 layer defect-free graphene platelets with an average size of hundreds of nm, and with a concentration of about 5.1 mg/mL characterized by Raman spectroscopy, atomic force microscopy (AFM), transmittance electron microscopy (TEM) and UV-vis spectroscopy. Further, a conductive ink was prepared and printed on flexible substrate (Polyimide) with controlled resolution. Scanning electron microscopy (SEM) and Profilometry revealed the effect of thermal annealing on the prints to concede consistent morphological characteristics. The resulted sheet resistance was measured to be R s = 36.75 Ω / sqr for prints as long as 100 mm. Printable inks were produced in volumes ranging from 20 mL to 1 L, with potential to facilitate large scale production of graphene for applications in biosensors, as well as flexible and printable electronics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.