Objectives: To retrospectively investigate the reliability of the age-based formula, year/4 + 3.5 mm in predicting size and year/2 + 12 cm in predicting insertion depth of preformed endotracheal tubes in children and correlate these data with the body mass index. Patients and Methods: Patients were classified into 4 groups according to their nutritional status: thinness, normal weight, overweight, and obesity; we then retrospectively compared the actual size of endotracheal tube and insertion depth to the predicting age-based formula and to the respective bend-to-tip distance of the used preformed tubes. Results: Altogether, 300 patients were included. The actual endotracheal tube size corresponded with the Motoyama formula (64.7%, 90% CI: 60.0-69.1), except for thin patients, where the calculated size was too large (0.5 mm). The insertion depth could be predicted within the range of the bend-to-tip distance and age-based formula in 85.0% (90% CI: 81.3-88.0) of patients. Conclusion: Prediction of the size of cuffed preformed endotracheal tubes using the formula of Motoyama was accurate in most patients, except in thin patients (body mass index < −2 SD). The insertion depth of the tubes was mostly in the range of the age-based-formula to the bend-to-tip distance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.