Background: Transesophageal echocardiography (TEE) is a valuable tool for monitoring the patient during transvenous lead extraction (TLE), but the direct impact of TEE on the effectiveness and safety of TLE has not yet been documented. Methods: The effectiveness of TLE and short-term survival were compared between two groups of patients: 2106 patients in whom TEE was performed before and after TLE and 1079 individuals in whom continuous TEE monitoring was used. The procedure-related risk of major complications was assessed using a predictive SAFeTY TLE score. Results: The patients monitored by TEE were characterized by older age, more comorbidities and higher SAFeTY TLE scores (6.143 ± 4.395 vs. 5.593 ± 4.127; p = 0.004). Complete procedural success was significantly higher in the TEE-guided group (97.683% vs. 95.442%, p < 0.01). The rate of serious complications in the TEE-guided group was lower than the predictive SAFeTY TLE score—a reduction of 28.75% (p < 0.05). Periprocedural mortality in the TEE-guided and non-TEE-guided groups was zero vs. six deaths (p = 0.186). Short-term survival was comparable between the groups. Conclusions: Transesophageal echocardiography as a monitoring tool during transvenous lead extraction provides valuable results—higher rates of complete procedural success and a reduced risk of the most severe complications, thus preventing periprocedural deaths.
Aims: The usefulness of transesophageal echocardiographic (TEE) monitoring for transvenous lead extraction (TLE) procedures is still controversial. The purpose of the current study was to present new TEE values in detecting invisible events in fluoroscopy and preventing the development of dangerous complications. Methods: From 2015 to 2019, a total of 1026 procedures were performed in single TLE center. In total, 1108 leads had been extracted with a mean lead dwell time of 115.8 ± 77.6 months. Continuous TEE was used in 936 patients with a mean age of 67.1 ± 14.4 years. Results: Preprocedure examination revealed looped leads in 181 (19.3%) patients, dry cardiac perforation in 151 (16.1%), lead-to-lead adhesion in 172 (18.4%), lead adhesion to the myocardium in 317 (33.9%), and vegetations in 119 (12.7%) patients.Intra-procedural TEE demonstrated pulling on the atrial wall, ventricular wall, or tricuspid valve in 380 (40.5%), 235 (25.1%), and 78 (8.3%) patients, respectively. Acute tamponade requiring sternotomy occurred in 11 (1.1%) patients. Migration of vegetation or connective tissue fragments were seen in 69 (7.3%) and 111 (11.8%) patients, respectively. After procedure, TEE was helpful in navigating an implantation, a new lead in 97 (10.3%) patients, and removing the remnants of lead/silicone insulation in 50 (5.3%) patients. Conclusion:Real time transesophageal echocardiography for the guidance of transvenous lead extraction informs the operator about the danger of manipulations close to delicate cardiac structures and whether immediate modification to the plan of lead removal is necessary in order to prevent the occurrence of unwanted events. K E Y W O R D S continuous echocardiographic monitoring, transesophageal echocardiography, transvenous lead extraction
Background: Little is known about lead-related venous stenosis/occlusion (LRVSO), and the influence of LRVSO on the complexity and outcomes of transvenous lead extraction (TLE) is debated in the literature. Methods: We performed a retrospective analysis of venograms from 2909 patients who underwent TLE between 2008 and 2021 at a high-volume center. Results: Advanced LRVSO was more common in elderly men with a high Charlson comorbidity index. Procedure duration, extraction of superfluous leads, occurrence of any technical difficulty, lead-to-lead binding, fracture of the lead being extracted, need to use alternative approach and lasso catheters or metal sheaths were found to be associated with LRVSO. The presence of LRVSO had no impact on the number of major complications including TLE-related tricuspid valve damage. The achievement of complete procedural or clinical success did not depend on the presence of LRVSO. Long-term mortality, in contrast to periprocedural and short-term mortality, was significantly worse in the groups with LRSVO. Conclusions: LRVSO can be considered as an additional TLE-related risk factor. The effect of LRVSO on major complications including periprocedural mortality and on short-term mortality has not been established. However, LRVSO has been associated with poor long-term survival.
Background: Transvenous lead extraction (TLE) is now a first-line technique for the treatment of complications related to cardiac implantable electronic devices. The aim of the study was to demonstrate that it is possible to safely perform difficult TLE procedures with a maximum reduction of peri-procedural major complications. Methods: A total of 1000 consecutive patients undergoing TLE in a single high-volume center from 2016 to 2019 were studied. All procedures were performed in a hybrid room or operating room by a specialized TLE team. TLE was performed under general anesthesia and monitored by transesophageal echocardiography, and the operating room was suitably equipped for immediate surgical intervention. The effectiveness and safety of the procedures were assessed, with particular emphasis on major complications. Results: In all, 1952 leads with the mean implant duration of 111.7 ± 77.6 months had been extracted. Complete procedural success of patients was achieved in 95.9% and clinical success in 99.1%. Major complications, predominantly cardiac tamponade (63.3%), occurred in 22 patients (2.2%). Rapid diagnosis and immediate intervention were the key to a 100% survival in patients with this complication. Conclusion:Performing procedures in a hybrid operating room under general anesthesia in the presence of a cardiac surgeon and with the use of transesophageal echocardiography significantly improves the safety of transvenous lead extraction.
Background: our knowledge of lead-related venous stenosis/occlusion (LRVSO) remains limited and there is still controversy regarding the risk factors for LRVSO. Venography is mandatory before transvenous lead extraction (TLE). Methods: we performed a retrospective analysis of venograms in 2909 patients (39.43% females, average age 66.90 years) who underwent TLE between 2008 and 2021 at high-volume centers. Results: the severity of LRVSO was likely to be dependent on the number of leads in the system (OR = 1.345; p = 0.003), the number of abandoned leads (OR = 1.965; p < 0.001), the presence of coronary sinus leads (OR = 1.184; p = 0.056), male gender (OR = 1.349; p = 0.003) and patient age at first CIED implantation (OR = 1.008; p = 0.021). The presence of permanent atrial fibrillation (OR = 0.666; p < 0.001) and right ventricular diastolic diameter (OR = 0.978; p = 0.006) showed an inverse correlation with the degree of LRVSO. The combined three-model multivariate analysis provided better prediction of LRSVO using the above-mentioned factors than the CHA2DS2-VASc score. Conclusions: the severity of LRVSO is probably dependent on the mechanical impact of the implanted/abandoned leads on the vein wall, therefore the study has demonstrated the central role of system-/procedure-related risk factors. The thrombotic mechanism may be less important, especially long after implantation, and for this reason the combined prediction model for LRVSO in this study was more effective than the CHA2DS2-VASc score.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.