The aim of this study was to determine and evaluate the temporal profiles of the concentration of chemical elements in the suspended particulate matter present inside a small bronze and an iron foundry industry. To collect the samples, we used a streaker sampler that separates particles with aerodynamic diameters smaller than 10 μm (PM 10 ) in two fractions: fine (particles with aerodynamic diameters less than 2.5 μm; PM 2.5 ) and coarse (between 2.5 μm and less than 10 μm; PM 10-2.5 ). The collection of samples was taken every 20 min during a total time of 8 and 5 h of molding and casting of bronze and iron, respectively. The samples collected in the form of strips on a filter (fine fraction) and an impactor (coarse fraction) were analyzed by the energy dispersive X-ray fluorescence technique. In the excitation, an X-ray tube with Mo target and Zr filter was used, operated at 30 mA/30 kV. For detecting the characteristic of X-rays, a semiconductor Si(Li) detector was used, coupled to a multi-channel spectrometer, with a 300 s excitation/detection time. The results of the temporal profiles of chemical element concentrations in coarse and fine fractions were discussed and compared with the maximum levels set by the Brazilian and international environmental agencies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.