ObjectiveThe aim of the present study was to verify the torque precision of metallic
brackets with MBT prescription using the canine brackets as the
representative sample of six commercial brands. Material and MethodsTwenty maxillary and 20 mandibular canine brackets of one of the following
commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP
Orthodontics, Morelli and Ortho Organizers. The torque angle, established by
reference points and lines, was measured by an operator using an optical
microscope coupled to a computer. The values were compared to those
established by the MBT prescription. ResultsThe results showed that for the maxillary canine brackets, only the Morelli
torque (-3.33º) presented statistically significant difference from the
proposed values (-7º). For the mandibular canines, American Orthodontics
(-6.34º) and Ortho Organizers (-6.25º) presented statistically significant
differences from the standards (-6º). Comparing the brands, Morelli
presented statistically significant differences in comparison with all the
other brands for maxillary canine brackets. For the mandibular canine
brackets, there was no statistically significant difference between the
brands. ConclusionsThere are significant variations in torque values of some of the brackets
assessed, which would clinically compromise the buccolingual positioning of
the tooth at the end of orthodontic treatment.
Effective orthodontic anchorage may be obtained by miniimplants inserted into the maxillary bones. However, the risk of miniimplant failure is one of the most important issues, especially the rupture of its structure referred to as fracture, mainly due to metal deficiencies. This study analyzed the internal microstructure of orthodontic mini-implants, ascertaining the composition of the metal to detect possible discontinuities from the surface to the core of the screws. Eighteen samples of mini-implants, of 3 different brands, were obtained. The samples were cold-embedded in methyl methacrylate polymer, and were sectioned both longitudinally (3 samples of each brand) and transversely (the other 3 screws of each brand). After preparation, the samples were observed using a light microscope at up to 2,000 x magnification. The results showed that the mini-implants thus analyzed were composed of an Alpha-Beta globular phase of titanium alloy, patterns A1 and A9 (in accordance with the "Technical Committee of European Titanium Producers"). The miniimplants did not present any defects such as bubbles, imperfections or fissures, in either longitudinal or transverse sections, in their internal microstructure. All samples met the requirements of international norms. Orthodontists must be aware of the metal composition and internal microstructure of mini-implants, to decrease the risk of fractures.
Aim: This experimental study investigated the association between masticatory hypofunction and mandibular morphological dimensions and internal bone characteristics. Methods: Twentyfour 21-day-old male Wistar rats were randomly divided into two groups, according to the diet consistency. The control group (CG) was fed a solid diet (pellets) and the experimental group (EG) received a powdered diet during 50 days. All animals were euthanized and their mandibles removed and processed for histomorphometric analysis. A calibrated examiner performed linear and angular measurements (mandibular body length and height, mandibular lengths, ramus depth and height, mandibular base depth, mandibular head and gonial angle) on photographs, estimated bone density in the mandibular ramus region on digital radiographs and assessed the area of cortical and trabecular bone tissue in the second molar region, in 5-µm-thick serial cuts stained with Cason's Trichrome. Measurements for the study groups were compared using Mann-Whitney test (α=0.05). Results: some of the macroscopic dimensions evaluated on photographs were significantly smaller in EG compared to CG, specifically mandibular ramus height (10.77 mm vs. 11.11 mm, p=0.0375), mandibular body length (21.67 mm vs. 22.36 mm, p=0.0165) and height (4.24 mm vs. 4.54 mm, p=0.0016), as well as mandibular base depth (1.24 mm vs. 1.47 mm, p=0.0325). The relative mineral bone density was significantly decreased in EG (1.04) compared to CG (1.25), p<0.001. Rats in the EG also presented smaller trabecular and cortical bone area (2.36 mm²) than those in CG (3.16 mm²), p<0.001. Conclusions: Based on the above-mentioned measurements, it may be concluded that masticatory hypofunction induced by a powdered diet affected mandibular morphology and was associated with significantly reduced bone content.
Our study found a significant positive correlation between periodontal disease and seizure severity. Epilepsy patients need to focus more on their oral health and quality of oral hygiene.
OBJETIVOS: este estudo transversal foi realizado com o objetivo de avaliar cefalometricamente a correlação da anatomia da base craniana com o padrão facial e as bases apicais. METODOLOGIA: foram utilizadas 88 telerradiografias de norma lateral de jovens leucodermas brasileiros com média de idade de 10,3 anos. Utilizou-se o índice VERT de Ricketts para a determinação do padrão facial, distribuindo a amostra em: 37 para o grupo M (mesofaciais), 34 para o grupo D (dolicofaciais) e 17 para o grupo B (braquifaciais). Realizaram-se, manualmente: o desenho anatômico, a demarcação de pontos, o traçado de linhas e planos e a aferição de medidas lineares e angulares. As medidas da base do crânio utilizadas foram S-N, N.S.Ba e S-N.Po-Or, e as medidas das bases apicais foram S.N.A, S.N.B e A.N.B. RESULTADOS E CONCLUSÕES: concluiu-se que, na correlação entre a base craniana e o padrão facial, houve significância entre a variável N.S.Ba e o índice VERT. Na correlação entre a base craniana e as bases apicais, houve significância entre N.S.Ba e as variáveis S.N.A e S.N.B, e entre S-N.Po-Or e as variáveis S.N.A e S.N.B.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.