PurposeWe aimed to determine myopia control efficacy with novel contact lenses (CL) that (1) reduced both central and peripheral defocus, and (2) provided extended depth of focus with better global retinal image quality for points on, and anterior to, the retina and degraded for points posterior to the retina.MethodsChildren (n = 508, 8–13 years) with cycloplegic spherical equivalent (SE) −0.75 to −3.50D were enrolled in a prospective, double blind trial and randomised to one of five groups: (1) single vision, silicone hydrogel (SH) CL; (2) two groups wearing SH CL that imposed myopic defocus across peripheral and central retina (test CL I and II; +1.00D centrally and +2.50 and +1.50 for CL I and II at 3 mm semi‐chord respectively); and (3) two groups wearing extended depth of focus (EDOF) hydrogel CL incorporating higher order aberrations to modulate retinal image quality (test CL III and IV; extended depth of focus of up to +1.75D and +2.50D respectively). Cycloplegic autorefraction and axial length (AL) measurements were conducted at six monthly intervals. Compliance to lens wear was assessed with a diary and collected at each visit. Additionally, subjective responses to various aspects of lens wear were assessed. The trial commenced in February 2014 and was terminated in January 2017 due to site closure. Myopia progression over time between groups was compared using linear mixed models and where needed post hoc analysis with Bonferroni corrections conducted.ResultsMyopia progressed with control CL −1.12 ± 0.51D/0.58 ± 0.27 mm for SE/AL at 24 months. In comparison, all test CL had reduced progression with SE/AL ranging from −0.78D to −0.87D/0.41–0.46 mm at 24 months (AL: p < 0.05 for all test CL; SE p < 0.05 for test CL III and IV) and represented a reduction in axial length elongation of about 22% to 32% and reduction in spherical equivalent of 24% to 32%. With test CL, a greater slowing ranging from 26% to 43% was observed in compliant wearers (≥6 days per week; Control CL: −0.64D/0.30 mm and −1.14D/0.58 mm vs test CL: −0.42D to −0.47D/0.12–0.18 mm and −0.70 to −0.81D/0.19–0.25 mm at 12 and 24 months respectively).ConclusionsContact lenses that either imposed myopic defocus at the retina or modulated retinal image quality resulted in a slower progression of myopia with greater efficacy seen in compliant wearers. Importantly, there was no difference in the myopia control provided by either of these strategies.
Both subjective comfort responses and AE rates varied according to the combination of lens type and care system in use. The combinations with the best comfort ratings did not necessarily have a favorable AE rate. Practitioners can maximize behavior with respect to both these factors by choosing an appropriate care system for the lenses they prescribe.
A hyperopic OK effect was established after 1 h with increased effect with longer lens wearing time. Central fenestrations did not affect the clinical outcomes, indicating that corneal compression by the lens in the para-central region as opposed to central post lens tear film suction may be the primary mechanism behind the hyperopic OK clinical effect.
A fundamental clinical skill is the recognition of artefacts within the outputs of advanced imaging modalities. However, current teaching programmes of healthcare practitioners are becoming increasingly challenged to provide practical exposure within an already crowded curriculum. This study evaluates the impact of a novel work-integrated teaching model on the confidence and competence of clinicians in the use of optical coherence tomography (OCT) and the recognition of its artefacts. The outcomes were then used to develop a model to predict performance and guide teaching strategies. Methods: We prospectively evaluated a 6-week clinical placement for final year optometry students within a diagnostic eye clinic in 2018-2020. Participants completed a quiz on the identification of common OCT artefacts and rated their confidence levels on key areas of OCT application using a five-point Likert scale. Both were completed before (pre-rotation) and after (post-rotation) the placement. The cohort was divided into two groups; the first group was used to assess the impact of the placement and derive the prediction model for post-placement performance, which was then validated against the second group. Results: A significant improvement in detecting OCT imaging artefacts was seen upon completion of the placement, which was greater in participants with lower entry level performance. Across all OCT artefact subtypes, there was an improvement in detecting segmentation error, delineation error and media opacities. A model predicting post-placement student performance was developed using entry level knowledge base as the key dependent variable. Self-rated confidence improved across all domains of OCT application but was not found to be a direct predictor of actual performance. Conclusions: These results highlight the benefit of a work-integrated learning programme on both academic performance and confidence whilst identifying entry level knowledge base as the key variable predicting improvement. Tailored teaching incorporating entering knowledge is the best predictor of improvement during clinical placements. Integrating clinicians into a work-integrated setting with tailored teaching and comprehensive practical exposure can be an effective method for training future or current healthcare professionals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.