In the context of the coronavirus disease 2019 (COVID-19) pandemic, the development and validation of rapid and easy-to-perform diagnostic methods are of high priority. This study was performed to evaluate a novel rapid antigen detection test (RDT) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in respiratory samples. Methods: The fluorescence immunochromatographic SARS-CoV-2 antigen test (Bioeasy Biotechnology Co., Shenzhen, China) was evaluated using universal transport medium with nasopharyngeal (NP) and oropharyngeal (OP) swabs from suspected COVID-19 cases. Diagnostic accuracy was determined in comparison to SARS-CoV-2 real-time (RT)-PCR. Results: A total of 127 samples were included; 82 were RT-PCR-positive. The median patient age was 38 years, 53.5% were male, and 93.7% were from the first week after symptom onset. Overall sensitivity and specificity were 93.9% (95% confidence interval 86.5-97.4%) and 100% (95% confidence interval 92.1-100%), respectively, with a diagnostic accuracy of 96.1% and Kappa coefficient of 0.9. Sensitivity was significantly higher in samples with high viral loads. Conclusions: The RDT evaluated in this study showed a high sensitivity and specificity in samples mainly obtained during the first week of symptoms and with high viral loads, despite the use of a non-validated sample material. The assay has the potential to become an important tool for early diagnosis of SARS-CoV-2, particularly in situations with limited access to molecular methods.
Based on current data we propose that the uninucleated-cyst-producing Entamoeba infecting 36 humans is called Entamoeba polecki and divided into four subtypes (ST1-ST4) and that 37Entamoeba coli is divided into two subtypes (ST1-ST2). New hosts for several species were 38 detected and while host specificity and genetic diversity of several species remain to be 39 clarified, it is clear that previous reliance on cultivated material has given us a misleading and 40 incomplete picture of variation within the genus Entamoeba.
21In the context of the Covid-19 pandemic, the development and validation of rapid and easy-to-22 perform diagnostic methods are of high priority. We compared the performance of four rapid 23 antigen detection tests for SARS-CoV-2 in respiratory samples. Immunochromatographic SARS-24CoV-2 assays from RapiGEN, Liming bio, Savant, and Bioeasy were evaluated using universal 25 transport medium containing naso-oropharyngeal swabs from suspected Covid-19 cases. The 26 diagnostic accuracy was determined in comparison to SARS-CoV-2 RT-PCR. A total of 111 27 samples were included; 80 were RT-PCR positive. Median patients' age was 40 years, 55% were 28 female, and 88% presented within the first week after symptom onset. The evaluation of the 29Liming bio assay was discontinued due to insufficient performance. The overall sensitivity 30 values of RapiGEN, Liming bio, and Bioeasy tests were 62.0% (CI95% 51.0-71.9), 16.7% 31 (CI95% 10.0-26.5), and 85.0% (CI95% 75.6-91.2), respectively, with specificities of 100%. 32Sensitivity was significantly higher in samples with high viral loads (RapiGEN, 84.9%; Bioeasy, 33 100%). The study highlighted the significant heterogeneity of test performance among evaluated 34 assays, which might have been influenced by the use of a non-validated sample material. The 35 high sensitivity of some tests demonstrated that rapid antigen detection has the potential to serve 36 as an alternative diagnostic method, especially in patients presenting with high viral loads in 37 early phases of infection. This is particularly important in situations with limited access to PCR or prolonged turnaround time. Further comparative evaluations are necessary to select 39 products with high performance among the growing market of diagnostic tests for SARS-CoV-2. 40 41
Background Active surveillance is necessary for improving the management and outcome of patients with candidemia. The aim of this study was to describe epidemiologic and clinical features of candidemia in children and adults in tertiary level hospitals in Chile. Methods We conducted a prospective, multicenter, laboratory-based survey study of candidemia in 26 tertiary care hospitals in Chile, from January 2013 to October 2017. Results A total of 780 episodes of candidemia were included, with a median incidence of 0.47/1,000 admissions. Demographic, clinical and microbiological information of 384 cases of candidemia, from 18 hospitals (7,416 beds), was included in this report. One hundred and thirty-four episodes (35%) occurred in pediatric patients and 250 (65%) in adult population. Candida albicans (39%), Candida parapsilosis (30%) and Candida glabrata (10%) were the leading species, with a significant difference in the distribution of species between ages. The use of central venous catheter and antibiotics were the most frequent risk factors in all age groups (> 70%). Three hundred and fifteen strains were studied for antifungal susceptibility; 21 strains (6.6%) were resistant to fluconazole, itraconazole, voriconazole, anidulafungin or micafungin. The most commonly used antifungal therapies were fluconazole (39%) and echinocandins (36%). The overall 30-day survival was 74.2%, significantly higher in infants (82%) and children (86%) compared with neonates (72%), adults (71%) and elderly (70%). Conclusions Our prospective, multicenter surveillance study showed a low incidence of candidemia in Chile, with high 30-day survival, a large proportion of elderly patients, C . glabrata as the third most commonly identified strain, a 6.6% resistance to antifungal agents and a frequent use of echinocandins.
Background Healthcare workers (HCWs) are at high risk of exposure to SARS-CoV-2. Cross-sectional studies have provided variable rates of seroprevalence in HCWs. Longitudinal assessments of the serological response to Covid-19 among HCWs are crucial to understanding the risk of infection and changes in antibody titers over time. We aimed to investigate seroprevalence and risk factors associated with seroconversion in a prospective cohort of HCWs during the peak of the first wave of the Covid-19 pandemic. Methods We conducted a longitudinal study among 446 front-line HCWsin a tertiary-care hospital in Chile from April to July 2020. IgG was determined monthly using two different ELISAs in serum samples of HCWs, during the three-month period. In each visit, demographic data, symptoms, risk factors, and exposure risks were also assessed. Results The overall seroprevalence at the end of the study period was 24% (95% CI20.2–28.3), with 43% of seropositive HCWs reporting no prior symptoms. Seroconversion rates significantly differed over the study period, from 2.1% to as high as 8.8% at the peak of the epidemic. There were no statistically significant differences observed between HCWs in direct clinical care of patients with Covid-19 and those working in low risk areas. Antibody titers appeared to wane over time. Conclusions HCWs were severely affected with a high rate of seroconversion that appeared to mirror the local epidemiological situation. A significant amount of participants underwent an asymptomatic infection, highlighting the need for improved surveillance policies. Antibody titers appear to wane over time; further studies to understand this finding’s impact on the risk of reinfection are warranted.
Background Real-Time Reverse-Transcription Polymerase Chain Reaction (RT-PCR) is currently the only recommended diagnostic method for SARS-CoV-2. However, rapid immunoassays for SARS-CoV-2 antigen could significantly reduce the COVID-19 burden currently weighing on laboratories around the world. Methods We evaluated the performance of two rapid fluorescence immunoassays (FIAs), SOFIA SARS Antigen FIA (Quidel Corporation, San Diego, CA, USA) and STANDARD F COVID-19 Ag FIA (SD Biosensor Inc., Gyeonggi-do, Republic of Korea), which use an automated reader. The study used 64 RT-PCR characterized clinical samples (32 positive; 32 negative), which consisted of nasopharyngeal swabs in universal transport medium. Results Of the 32 positive specimens, all from patients within 5 days of symptom onset, the Quidel and SD Biosensor assays detected 30 (93.8%) and 29 (90.6%) samples, respectively. Among the 27 samples with high viral loads (Ct ≤ 25), the two tests had a sensitivity of 100%. Specificity was 96.9% for both kits. Conclusion The high performance of the evaluated FIAs indicates a potential use as rapid and PCR-independent tools for COVID-19 diagnosis in early stages of infection. The excellent sensitivity to detect cases with viral loads above ~106 copies/mL (Ct values ≤ 25), the estimated threshold of contagiousness, suggests that the assays might serve to rapidly identify infective individuals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.