Background Patients with COVID-19 seem to be prone to the development of arrhythmias. The objective of this trial was to determine the characteristics, clinical significance and therapeutic consequences of these arrhythmias in COVID-19 patients requiring intensive care unit (ICU) treatment. Methods and results A total of 113 consecutive patients (mean age 64.1 ± 14.3 years, 30 (26.5%) female) with positive PCR testing for SARS-CoV2 as well as radiographically confirmed pulmonary involvement admitted to the ICU from March to May 2020 were included and observed for a cumulative time of 2321 days. Fifty episodes of sustained atrial tachycardias, five episodes of sustained ventricular arrhythmias and thirty bradycardic events were documented. Sustained new onset atrial arrhythmias were associated with hemodynamic deterioration in 13 cases (35.1%). Patients with new onset atrial arrhythmias were older, showed higher levels of Hs-Troponin and NT-proBNP, and a more severe course of disease. The 5 ventricular arrhythmias (two ventricular tachycardias, two episodes of ventricular fibrillation, and one torsade de pointes tachycardia) were observed in 4 patients. All episodes could be terminated by immediate defibrillation/cardioversion. Five bradycardic events were associated with hemodynamic deterioration. Precipitating factors could be identified in 19 of 30 episodes (63.3%), no patient required cardiac pacing. Baseline characteristics were not significantly different between patients with or without bradycardic events. Conclusion Relevant arrhythmias are common in severely ill ICU patients with COVID-19. They are associated with worse courses of disease and require specific treatment. This makes daily close monitoring of telemetric data mandatory in this patient group.
Background High‐power (HP) ablation protocols are increasingly used for ablation procedures to shorten procedural times and improve short‐ and long‐term success. The ablation index (AI) combines contact force, power settings, and ablation time. It can be used in combination with HP protocols to guide operators toward standardized lesions. The purpose of this study was to evaluate both a HP and AI‐guided strategy for ablation of the cavotricuspid isthmus (CTI) in patients with typical atrial flutter (AFL). Methods In this single‐center study, consecutive patients with typical AFL (n = 52, mean age 68.7 ± 8.3 years, 21/52 [40.4%] female) underwent AI‐guided HP radiofrequency (RF) ablation of the CTI. Ablation was performed with 50 W and AI target values of 550 with a maximum ablation duration of 25 seconds per lesion. Target interlesion distance was ≤6 mm. Ablation was performed with a 3.5 mm porous tip Smarttouch SF catheter. Results Acute CTI block was achieved in 52 of 52 patients (100%), and first‐pass conduction block was achieved in 41 of 52 patients (80.4%). Spontaneous reconduction after 30 minutes waiting time occurred in 1 of 52 (1.9%) patient. Average ablation time until CTI block was 3:51 ± 1:40; 2:33 ± 1:01 minutes of bonus ablation pulses were applied after CTI block. An audible steam pop was noted in one patient (1.9%). No major complications occurred. After a mean follow‐up of 193.7 ± 152.2 days, no patient showed recurrence of typical AFL. Conclusion In this pilot study, AI‐guided HP ablation of the CTI was fast, safe, and effective.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.