Three-dimensional surgical planning is used widely in orthognathic surgery. Although numerous computer programs exist, the accuracy of soft tissue prediction remains uncertain. The purpose of this study was to compare the prediction accuracy of Dolphin, ProPlan CMF, and a probabilistic finite element method (PFEM). Seven patients (mean age 18 years; five female) who had undergone Le Fort I osteotomy with preoperative and 1-year postoperative cone beam computed tomography (CBCT) were included. The three programs were used for soft tissue prediction using planned and postoperative maxillary position, and these were compared to postoperative CBCT. Accurate predictions were obtained with each program, indicated by root mean square distances: RMS Dolphin = 1.8 AE 0.8 mm, RMS ProPlan = 1.2 AE 0.4 mm, and RMS PFEM = 1.3 AE 0.4 mm. Dolphin utilizes a landmark-based algorithm allowing for patient-specific bone-to-soft tissue ratios, which works well for cephalometric radiographs but has limited three-dimensional accuracy, whilst ProPlan and PFEM provide better three-dimensional predictions with continuous displacements. Patient or population-specific material properties can be defined in PFEM, while no soft tissue parameters are adjustable in ProPlan. Important clinical considerations are the topological differences between predictions due to the three algorithms, the
Current computational tools for planning and simulation in plastic and reconstructive surgery lack sufficient precision and are time-consuming, thus resulting in limited adoption. Although computer-assisted surgical planning systems help to improve clinical outcomes, shorten operation time and reduce cost, they are often too complex and require extensive manual input, which ultimately limits their use in doctor-patient communication and clinical decision making. Here, we present the first large-scale clinical 3D morphable model, a machine-learning-based framework involving supervised learning for diagnostics, risk stratification, and treatment simulation. The model, trained and validated with 4,261 faces of healthy volunteers and orthognathic (jaw) surgery patients, diagnoses patients with 95.5% sensitivity and 95.2% specificity, and simulates surgical outcomes with a mean accuracy of 1.1 ± 0.3 mm. We demonstrate how this model could fully-automatically aid diagnosis and provide patient-specific treatment plans from a 3D scan alone, to help efficient clinical decision making and improve clinical understanding of face shape as a marker for primary and secondary surgery.
Repositioning of the maxilla in orthognathic surgery is carried out for functional and aesthetic purposes. Pre-surgical planning tools can predict 3D facial appearance by computing the response of the soft tissue to the changes to the underlying skeleton. The clinical use of commercial prediction software remains controversial, likely due to the deterministic nature of these computational predictions. A novel probabilistic finite element model (FEM) for the prediction of postoperative facial soft tissues is proposed in this paper. A probabilistic FEM was developed and validated on a cohort of eight patients who underwent maxillary repositioning and had pre- and postoperative cone beam computed tomography (CBCT) scans taken. Firstly, a variables correlation assessed various modelling parameters. Secondly, a design of experiments (DOE) provided a range of potential outcomes based on uniformly distributed input parameters, followed by an optimisation. Lastly, the second DOE iteration provided optimised predictions with a probability range. A range of 3D predictions was obtained using the probabilistic FEM and validated using reconstructed soft tissue surfaces from the postoperative CBCT data. The predictions in the nose and upper lip areas accurately include the true postoperative position, whereas the prediction under-estimates the position of the cheeks and lower lip. A probabilistic FEM has been developed and validated for the prediction of the facial appearance following orthognathic surgery. This method shows how inaccuracies in the modelling and uncertainties in executing surgical planning influence the soft tissue prediction and it provides a range of predictions including a minimum and maximum, which may be helpful for patients in understanding the impact of surgery on the face.
Trigonocephaly in patients with metopic synostosis is corrected by fronto-orbital remodelling (FOR). The aim of this study was to quantitatively assess aesthetic outcomes of FOR by capturing 3D forehead scans of metopic patients pre- and post-operatively and comparing them with controls. Ten single-suture metopic patients undergoing FOR and 15 age-matched non-craniosynostotic controls were recruited at Great Ormond Street Hospital for Children (UK). Scans were acquired with a three-dimensional (3D) handheld camera and post-processed combining 3D imaging software. 3D scans were first used for cephalometric measurements. Statistical shape modelling was then used to compute the 3D mean head shapes of the three groups (FOR pre-op, post-op and controls). Head shape variations were described via principal component analysis (PCA). Cephalometric measurements showed that FOR significantly increased the forehead volume and improved trigonocephaly. This improvement was supported visually by pre- and post-operative computed mean 3D shapes and numerically by PCA (p < 0.001). Compared with controls, post-operative scans showed flatter foreheads (p < 0.001). In conclusion, 3D scanning followed by 3D statistical shape modelling enabled the 3D comparison of forehead shapes of metopic patients and non-craniosynostotic controls, and demonstrated that the adopted FOR technique was successful in correcting bitemporal narrowing but overcorrected the rounding of the forehead.
Apert syndrome children have a larger intracranial volume than children with other syndromic craniosynostotic conditions and unaffected children but maintain a similar occipitofrontal circumference. This study demonstrates high correlation between intracranial volume and occipitofrontal circumference with clinical care implications. The authors' reference growth curves can be used to monitor intracranial volume change over time and correct operative change for underlying growth.
A realistic mock circulatory system (MCS) could be a valuable in vitro testbed to study human circulatory hemodynamics. The objective of this study was to design a MCS replicating the pulmonary arterial circulation, incorporating an anatomically representative arterial model suitable for testing clinically relevant scenarios. A second objective of the study was to ensure the system's compatibility with magnetic resonance imaging (MRI) for additional measurements. A latex pulmonary arterial model with two generations of bifurcations was manufactured starting from a 3D-printed mold reconstructed from patient data. The model was incorporated into a MCS for in vitro hydrodynamic measurements. The setup was tested under physiological pulsatile flow conditions and results were evaluated using wave intensity analysis (WIA) to investigate waves traveling in the arterial system. Increased pulmonary vascular resistance (IPVR) was simulated as an example of one pathological scenario. Flow split between right and left pulmonary artery was found to be realistic (54 and 46%, respectively). No substantial difference in pressure waveform was observed throughout the various generations of bifurcations. Based on WIA, three main waves were identified in the main pulmonary artery (MPA), that is, forward compression wave, backward compression wave, and forward expansion wave. For IPVR, a rise in mean pressure was recorded in the MPA, within the clinical range of pulmonary arterial hypertension. The feasibility of using the MCS in the MRI scanner was demonstrated with the MCS running 2 h consecutively while Address correspondence and reprint requests to: Paul Knoops, 30 Guilford Street, London WC1N 1EH, UK. paul.knoops. 14@ucl.ac.uk. Author ContributionsConception and design of the work: PGMK, GB, ADH, SS, RT; experimental setup, data acquisition and analysis: PGMK, GB, LX; interpretation of the data: PGMK, GB, ADH, KHP, RT; drafting the manuscript: PGMK, GB, RT; all authors critically revised the manuscript, read and approved the final manuscript. Conflict of InterestThe authors declare no conflict of interest. Europe PMC Funders GroupAuthor Manuscript Artif Organs. Author manuscript; available in PMC 2017 July 15. Published in final edited form as:Artif Organs. 2017 July ; 41(7): 637-646. doi:10.1111/aor.12809. Europe PMC Funders Author ManuscriptsEurope PMC Funders Author Manuscripts acquiring preliminary MRI data. This study shows the development and verification of a pulmonary MCS, including an anatomically correct, compliant latex phantom. The setup can be useful to explore a wide range of hemodynamic questions, including the development of patientand pathology-specific models, considering the ease and low cost of producing rapid prototyping molds, and the versatility of the setup for invasive and noninvasive (i.e., MRI) measurements.Mock circulatory systems (MCS) are widely used to gather hydrodynamic data in vitro. They allow investigation of the cardiovascular system in both healthy and pathological scenarios, with t...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.