Introduction High tibial osteotomy (HTO) is a surgical procedure aimed at inhibiting the progression of osteoarthritis of the knee joint. The aim of this study was to identify factors influencing the functional outcome after opening wedge valgus HTO. Methods A total of 175 cases (155 patients) of varus-correcting high tibial open-wedge osteotomies using the Tomofix plate were reviewed retrospectively. Patients answered the Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaire and 4 survey follow-up questions. Results and Discussion A total of 76 of the 155 patients studied (84 of the 175 knees) completed the KOOS questionnaire, on average 3.1 years (SD 1.8 years) after the surgery. The median scores (with median absolute deviations [MAD]) for the KOOS pain, symptoms, daily activities, sports, and quality of life sections were, respectively, 76.4 (MAD 12.5), 75.0 (MAD 14.3), 85.3 (MAD 11.8), 50.0 (MAD 25.0), and 59.4 (MAD 21.9). No cases of nonunion were observed throughout the length of the study. Identified predictors of worse outcomes were higher weight and body mass index, limited knee flexion, genu varum and tibial varus of small magnitude, active smoking status at the time of surgery, further surgery for plate removal, and some grades of chondropathy in the patellofemoral, medial tibial, and femoral compartments. Patient gender, joint obliquity and over- or undercorrection were not associated with any of the outcomes. Conclusion This study shows good results following valgus HTO that are comparable to outcomes following total knee arthroplasty, reinforcing the option of HTO as a valid alternative for total knee arthroplasty.
BACKGROUND Instability is a major cause of failure of revision total hip arthroplasty (THA) which can be avoided with the use of monobloc press-fit cups with large diameter heads (LDH). OBJECTIVE This consecutive case series analyses whether LDH monobloc components are a safe and clinically beneficial option for revision THA. METHODS This consecutive case series includes 47 revision THA with LDH monobloc acetabular cup. Acetabular bone defects were Paprosky type I (42), type IIA (2) and type IIC (3). The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Forgotten Joint Score (FJS) and the Patient’s Joint Perception (PJP) scores were analysed and a radiographic evaluation for signs of implant dysfunction was performed. RESULTS After a mean follow-up of 4.5 years, there were 5 (10.6%) acetabular cup re-revisions: 2 loss of primary fixation and 3 instabilities. Implant survivorship at 4-years was 89.4% (95% CI: 89.3 to 89.5). Recurrent hip dislocation was reported in 1 patient (2.1%) and remains under conservative treatment. The mean WOMAC and FJS were 19.5 (16.8; 0.0 to 58.3) and 57.3 (28.9; 6.3 to 100.0), respectively. Regarding the PJP, 3 (8.8%) patients perceived their hip as natural, 8 (23.5%) as an artificial joint with no restriction, 14 (41.2%) with minor restriction and 9 (26.5%) with major restriction. CONCLUSION In cases of revision THA with limited bone loss, press-fit primary fixation with LDH monobloc acetabular components are valuable options that offer excellent mid-term out-comes with low re-revision and joint instability rates.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.