For the purpose of assessing combustion effects in a small gas turbine engine, there was a requirement to evaluate the rotating temperature and dynamic characteristics of the power turbine rotor module. This assessment required measurements be taken within the engine, during operation up to maximum power, using rotor mounted thermocouples and strain gages. The acquisition of this data necessitated the use of a telemetry system that could be integrated into the existing engine architecture without affecting performance. Due to space constraints, housing of the telemetry module was limited to placement in a hot section. In order to tolerate the high temperature environment, a cooling system was developed as part of the integration effort to maintain telemetry module temperatures within the limit allowed by the electronics. Finite element thermal analysis was used to guide the design of the cooling system. This was to ensure that sufficient airflow was introduced and appropriately distributed to cool the telemetry cavity, and hence electronics, without affecting the performance of the engine. Presented herein is a discussion of the telemetry system, instrumentation design philosophy, cooling system design and verification, and sample of the results acquired through successful execution of the full engine test program.
Rolls-Royce Dahlewitz, GermanyFor the purpose of assessing combustion effects in a small gas turbine engine, there was a requirement to evaluate the rotating temperature and dynamic characteristics of the power turbine rotor module. This assessment reqtdred measurements be taken within the engine, during operation up to maximum power, using rotor mounted thermocouples and strain gauges. The acquisition of this data necessitated the use of a telemetry system that could be integrated into the existing engine architecture without affecting performance. As a result of space constraints, housing of the telemetry module was limited to placement in a hot section. To tolerate the high temperature environment, a cooling system was developed as part of the integration effort to maintain telemetry module temperatures within the limit allowed by the electronics. Finite element thermal analysis was used to guide the design of the cooling system. This was to ensure that sufficient airflow was introduced and appropriately distributed to cool the telemetry cavity, and hence electronics, without affecting the performance of the engine. Presented herein is a discussion of the telemetry system, instrumentation design philosophy, cooling system design and verification, and sample of the results acquired through successful execution of the full engine test program.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.