Notwithstanding the advancement of modern bionic hands and the large variety of prosthetic hands in the market, commercial devices still present limited acceptance and percentage of daily use. While commercial prostheses present rigid mechanical structures, emerging trends in the design of robotic hands are moving towards soft technologies. Although this approach is inspired by nature and could be promising for prosthetic applications, there is scant literature concerning its benefits for end-users and in real-life scenarios. In this work, we evaluate and assess the role and the benefits of soft robotic technologies in the field of prosthetics. We propose a thorough comparison between rigid and soft characteristics of two poly-articulated hands in 5 non-expert myo-electric prosthesis users in pre- and post-therapeutic training conditions. The protocol includes two standard functional assessments, three surveys for user-perception, and three customized tests to evaluate the sense of embodiment. Results highlight that rigid hands provide a more precise grasp, while soft properties show higher functionalities thanks to their adaptability to different requirements, intuitive use and more natural execution of activities of daily living. This comprehensive evaluation suggests that softness could also promote a quick integration of the system in non-expert users.
To physically interact with a rich variety of environments and to match situation-dependent requirements, humans adapt both the force and stiffness of their limbs. Reflecting this behavior in prostheses may promote a more natural and intuitive control and, consequently, improve prostheses acceptance in everyday life. This pilot study proposes a method to control a prosthetic robot hand and its impedance, and explores the utility of variable stiffness when performing activities of daily living and physical social interactions. The proposed method is capable of a simultaneous and proportional decoding of position and stiffness intentions from two surface electro-myographic sensors placed over a pair of antagonistic muscles. The feasibility of our approach is validated and compared to existing control modalities in a preliminary study involving one prosthesis user. The algorithm is implemented in a soft under-actuated prosthetic hand (SoftHand Pro). Then, we evaluate the usability of the proposed approach while executing a variety of tasks. Among these tasks, the user interacts with other 12 able-bodied subjects, whose experiences were also assessed. Several statistically significant aspects from the System Usability Scale indicate user's preference of variable stiffness control over low or high constant stiffness due to its reactivity and adaptability. Feedback reported by able-bodied subjects reveal a general tendency to favor soft interaction, i.e., low stiffness, which is perceived more human-like and comfortable. These combined results suggest the use of variable stiffness as a viable compromise between firm control and safe interaction which is worth investigating further.
Although recent technological developments in the field of bionic upper limb prostheses, their rejection rate remains excessively high. The reasons are diverse (e.g. lack of functionality, control complexity, and comfortability) and most of these are reported only through self-rated questionnaires. Indeed, there is no quantitative evaluation of the extent to which a novel prosthetic solution can effectively address users’ needs compared to other technologies. This manuscript discusses the challenges and limitations of current upper limb prosthetic devices and evaluates their functionality through a standard functional assessment, the Assessment of Capacity for Myoelectric Control (ACMC). To include a good representation of technologies, the authors collect information from participants in the Cybathlon Powered Arm Prostheses Race 2016 and 2020. The article analyzes 7 hour and 41 min of video footage to evaluate the performance of different prosthetic devices in various tasks inspired by activities of daily living (ADL). The results show that commercially-available rigid hands perform well in dexterous grasping, while body-powered solutions are more reliable and convenient for competitive environments. The article also highlights the importance of wrist design and control modality for successful execution of ADL. Moreover, we discuss the limitations of the evaluation methodology and suggest improvements for future assessments. With regard to future development, this work highlights the need for research in intuitive control of multiple degrees of freedom, adaptive solutions, and the integration of sensory feedback.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.