The time-resolved electric field in a fast ionization wave discharge in a diffuse nanosecond pulse discharge plasma in atmospheric pressure air is measured using the Electric Field Induced Second Harmonic (E-FISH) diagnostic. The electric field is placed on an absolute scale by calibration against a Laplacian field. At relatively low peak voltages, when the plasma is generated only near the pin high-voltage electrode, the electric field is measured ahead of the ionization wave during the entire voltage pulse, exhibiting a strong field enhancement compared to the Laplacian field, by about an order of magnitude. As the peak voltage is increased and the ionization wave traverses the laser beam, the electric field is measured both ahead of the wave and behind the ionization front, where the field drops rapidly due to the charge separation and plasma selfshielding. When the wave reaches the grounded electrode, the discharge transitions into a conduction phase in which the potential is redistributed within the gap. The electric field in the vicinity of the pin then increases again, following the applied voltage waveform for the rest of the pulse. The effective time resolution of the present measurements is 150 ps. Based on the single shot data, we find that the peak electric field in the wave front is moderately influenced by the applied voltage and varies between 160 to 210 kV/cm. This study demonstrates the viability of the E-FISH diagnostic for this class of atmospheric pressure discharges and paves the way for future in-depth studies of this particular problem.
This work presents spatial (axial-z and transversal-y) and temporal distributions of Ar(1s 5 ) metastable absolute densities in an atmospheric pressure argon micro-plasma jet impinging on an ungrounded glass surface. Guided streamers are generated with a DBD device driven by pulsed positive high voltages of 6 kV in amplitude, 224 3 ns in FWHM and 20 kHz in frequency. The argon flow rate is varied between 200 and 600 sccm. The glass plate is placed at 5 mm away from the reactor's nozzle and perpendicular to the streamers propagation. At these conditions, a diffuse stable discharge is established after the passage of the streamers allowing the quantification of the Ar(1s 5 ) absolute density by means of a conventional TDLAS technique coupled with emission spectroscopy and ICCD imaging. The good reproducibility of the absorption signals is demonstrated. The experiments show the strong dependence of the maximum density 0.5 4 10 cm 13 3-´-() on the gas flow rate and the axial and transversal position. At 200 sccm, high maximum densities 2.4 10 cm 13 3 >´-() are obtained in a small area close to the plasma source, while with increasing flow rate this area expands towards the glass plate. In the transversal direction, density maxima are obtained in a small zone around the propagation axis of the streamers. Finally, a noticeable increase is measured on the Ar(1s 5 ) effective lifetime close to the glass surface by varying the flow rate from 200 to 600 sccm. In overall, the effective lifetime varies between ∼25 and ∼550 ns, depending on the gas flow rate and the values of z and y coordinates. The results obtained suggest that the present system can be implemented in various applications and particularly in what concerns the detection of weakly volatile organic compounds present in trace amounts on different surfaces.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.