Introduction: Closed reduction and cast application is still regarded as first line treatment for pediatric tibial fractures. Over the past few decades, management of pediatric tibial fractures has shifted more towards operative intervention because of quicker recovery, shorter rehabilitation period, less immobilization, lack of stiffness of adjoining joints, and less psychological impact to the children. Flexible intramedullary nails not only fulfill the above advantage but also maintain alignment and rotation.Methods: This was a retrospective study of pediatric tibial fractures fixed with two titanium elastic nails through proximal ends of bones. Alignment of fracture, any infection, delayed union, non union, limb length discrepancy, motion of knee joint, and fracture union time were measured during follow-up examination.Results: Forty-five patients were enrolled into the study out of which 28 (62.2%) were male and 17 (37.8%) were female. Average age of patient was 9.48±2.17 years and average time taken to heal the fractures (both clinical and radiological) was 11.17±2.81 weeks. There were 2 (4.4%) of malunion, 4 (8.8%) of delayed union, 3 (6.6%) of limb shortening, 2 (4.4%) of limb lengthening, 6 (13.6%) of nail prominence and skin irritation, 2 (4.4%) of superficial infection at nail entry site and one case of re-fracture.Conclusions: Titanium elastic nail fixation is a simple, easy, rapid, reliable and effective method for management of pediatric tibial fractures in patients with operative indications. There may be the chances of complication following the TENS in tibia but these are avoidable as well as manageable with careful precautions. Keywords: complications; functional outcomes; tibia fractures. | PubMed
The management of displaced, intra-articular calcaneal fracture represents a surgical challenge to even an experienced orthopedic surgeon. Plate osteosynthesis using an extended lateral approach is complicated by soft tissue problems, while those treated by closed reduction and percutaneous pinning cannot address all the intra-articular fragments sufficiently. The objective of our study is to evaluate restoration of subtalar joint and long-term functional outcomes in intra-articular displaced calcaneal fractures treated with transverse subcondral screws through a small incision on lateral aspect of calcaneus and percutaneously placed axial screws through the calcaneal tuberosity. Forty-five intra-articular calcaneal fractures were managed with this minimally invasive technique. Calcaneal height, width, length, Bohler's angle, and Gissane angle were measured preoperatively and last follow-up visit. Functional outcomes were assessed on the basis of American Orthopedic Foot and Ankle Society (AOFAS) ankle/hind foot score. Preoperative calcaneal length, height, width, Bohler's angle, and Gissane angle were improved from 68.62 ± 2.64 to 72.44 ± 2.63 mm, 39.28 ± 2.72 to 32.37 ± 2.65 mm, 47.04 ± 2.56 to 49.55 ± 2.45 mm, 12.66° ± 2.86° to 26.93° ± 2.57°, 123.91° ± 3.13° to 96.06° ± 3.92°, respectively, after surgery with P value <0.001. There were 21 (46.7%) excellent, 17 (37.8%) good, 4 (8.8%) fair, and 3 (6.7%) poor outcomes based on AOFAS ankle/hindfoot scores. Time to unite the fracture was 11.06 ± 1.82 weeks (range 8-16 weeks), and all fractures were united without major complications. Minimally invasive technique through a small incision on lateral aspect of calcaneus gives a moderately good exposure for anatomical restoration of Sander's type II and III calcaneal fractures fixed with both transverse and axial screws under fluoroscopic guidance.
Bone grafting and Herbert screw fixation provides a good option for treatment of scaphoid nonunion, especially in the absence of avascular necrosis of proximal fragment. More importantly, vascularized bone grafting in all scaphoid nonunion may not be necessary and could otherwise have been united uneventfully by this technique. However, avascular necrosis of proximal fragment must be ruled out pre-operatively as well as intra-operatively.
Introduction: Various treatment modalities are available but no consensus has been reached for optimal treatment of lateral third clavicle fractures. Precontoured locking plates with broad lateral end for multiple screws fixation is a newly designed plate for lateral third clavicle fractures. The objective of our study was to analyse the functional outcomes as well as complications of this technique in a significant number of cases with long follow-up duration.Materials and Methods: Forty-six patients with distal third clavicle fractures were treated by precontoured clavicular locking plate with broad lateral end. Functional outcomes were assessed on the basis of Constant-Murley Shoulder Outcome Score and University of California, Los Angeles (UCLA) Shoulder Rating Score, active shoulder range of motion, time for fracture union and coraco-clavicular distance.Results: The mean Constant-Murley score was 92.56±4.47 (range: 79-98) for injured side and 96.22±2.23 (range: 90-100) for normal side with p-Value 0.56. Mean coraco-clavicular distance at final follow-up was 10.52±1.13 mm (range 9.7 to 11.7 mm) in injured side and 10.25±0.98 mm (range 9.6 to 11.2 mm) in normal side. Mean UCLA Shoulder Rating Score was 32.55±2.12 (range: 27-34) for injured side and 33.46±1.88 (range: 31- 35) on normal side with p value 0.58. No major complications that necessitated revision of surgery occurred in our study.Conclusion: This newly designed plate seemed extremely useful in successful union of lateral third clavicle fractures, with reduced rate of complications like fixation failures, iatrogenic rotator cuff injury, AC joint osteoarthritis and sub-acromial bursitis, with good functional outcomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.