Experiments and numerical computations are performed to investigate the convective heat transfer characteristics of a gas turbine can combustor under cold flow conditions in a Reynolds number range between 50,000 and 500,000 with a characteristic swirl number of 0.7. It is observed that the flow field in the combustor is characterized by an expanding swirling flow, which impinges on the liner wall close to the inlet of the combustor. The impinging shear layer is responsible for the peak location of heat transfer augmentation. It is observed that as Reynolds number increases from 50,000 to 500,000, the peak heat transfer augmentation ratio (compared with fully developed pipe flow) reduces from 10.5 to 2.75. This is attributed to the reduction in normalized turbulent kinetic energy in the impinging shear layer, which is strongly dependent on the swirl number that remains constant at 0.7 with Reynolds number. Additionally, the peak location does not change with Reynolds number since the flow structure in the combustor is also a function of the swirl number. The size of the corner recirculation zone near the combustor liner remains the same for all Reynolds numbers and hence the location of shear layer impingement and peak augmentation does not change.
In this paper, we compute Laplacian energy of the non-commuting graphs of some classes of finite non-abelian groups.
Modern dry low emissions (DLE) combustors are characterized by highly swirling and expanding flows that makes the convective heat load on the gas side difficult to predict and estimate. A coupled experimental–numerical study of swirling flow inside a DLE annular combustor model is used to determine the distribution of heat transfer on the liner walls. Three different Reynolds numbers are investigated in the range of 210,000–840,000 with a characteristic swirl number of 0.98. The maximum heat transfer coefficient enhancement ratio decreased from 6 to 3.6 as the flow Reynolds number increased from 210,000 to 840,000. This is attributed to a reduction in the normalized turbulent kinetic energy in the impinging shear layer, which is strongly dependent on the swirl number that remains constant at 0.98 for the Reynolds number range investigated. The location of peak heat transfer did not change with the increase in Reynolds number since the flow structures in the combustors did not change with Reynolds number. Results also showed that the heat transfer distributions in the annulus have slightly different characteristics for the concave and convex walls. A modified swirl number accounting for the step expansion ratio is defined to facilitate comparison between the heat transfer characteristics in the annular combustor with previous work in a can combustor. A higher modified swirl number in the annular combustor resulted in higher heat transfer augmentation and a slower decay with Reynolds number.
This paper describes the design and testing of a catalytically-stabilized pilot burner for current and advanced Dry Low NOx (DLN) gas turbine combustors. In this paper, application of the catalytic pilot technology to industrial engines is described using Solar Turbines’ Taurus 70 engine. The objective of the work described is to develop the catalytic pilot technology and document the emission benefits of catalytic pilot technology when compared to higher, NOx producing pilots. The catalytic pilot was designed to replace the existing pilot in the existing DLN injector without major modification to the injector. During high pressure testing, the catalytic pilot showed no incidence of flashback or autoignition while operating over wide range of combustion temperatures. The catalytic reactor lit off at a temperature of approximately 598K (325°C/617°F) and operated at simulated 100% and 50% load conditions without a preburner. At high pressure, the maximum catalyst surface temperature was similar to that observed during atmospheric pressure testing and considerably lower than the surface temperature expected in lean-burn catalytic devices. In single injector rig testing, the integrated assembly of the catalytic pilot and Taurus 70 injector demonstrated NOx and CO emission less than 5 ppm @ 15% O2 for 100% and 50% load conditions along with low acoustics. The results demonstrate that a catalytic pilot burner replacing a diffusion flame or partially-premixed pilot in an otherwise DLN combustor can enable operation at conditions with substantially reduced NOx emissions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.