Background - COVID-19 has led to over 1 million deaths worldwide and has been associated with cardiac complications including cardiac arrhythmias. The incidence and pathophysiology of these manifestations remain elusive. In this worldwide survey of patients hospitalized with COVID-19 who developed cardiac arrhythmias, we describe clinical characteristics associated with various arrhythmias, as well as global differences in modulations of routine electrophysiology practice during the pandemic. Methods - We conducted a retrospective analysis of patients hospitalized with COVID-19 infection worldwide with and without incident cardiac arrhythmias. Patients with documented atrial fibrillation (AF), atrial flutter (AFL), supraventricular tachycardia (SVT), non-sustained or sustained ventricular tachycardia (VT), ventricular fibrillation (VF), atrioventricular block (AVB), or marked sinus bradycardia (HR<40bpm) were classified as having arrhythmia. De-identified data was provided by each institution and analyzed. Results - Data was collected for 4,526 patients across 4 continents and 12 countries, 827 of whom had an arrhythmia. Cardiac comorbidities were common in patients with arrhythmia: 69% had hypertension, 42% diabetes mellitus, 30% had heart failure and 24% coronary artery disease. Most had no prior history of arrhythmia. Of those who did develop an arrhythmia, the majority (81.8%) developed atrial arrhythmias, 20.7% developed ventricular arrhythmias, and 22.6% had bradyarrhythmia. Regional differences suggested a lower incidence of AF in Asia compared to other continents (34% vs. 63%). Most patients in in North America and Europe received hydroxychloroquine, though the frequency of hydroxychloroquine therapy was constant across arrhythmia types. Forty-three percent of patients who developed arrhythmia were mechanically ventilated and 51% survived to hospital discharge. Many institutions reported drastic decreases in electrophysiology procedures performed. Conclusions - Cardiac arrhythmias are common and associated with high morbidity and mortality among patients hospitalized with COVID-19 infection. There were significant regional variations in the types of arrhythmias and treatment approaches.
Background: The Subcutaneous ICD (S-ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, less left ventricular dysfunction and received more inappropriate shocks (IAS) than in typical transvenous (TV)-ICD trials. The UNTOUCHED trial was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms. Methods: Primary prevention patients with left ventricular ejection fraction (LVEF) ≤ 35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥ 250 beats per minute (bpm) and morphology discrimination for rates ≥200 and < 250 bpm. Patients were followed for 18 months. The primary endpoint was the IAS free rate compared to a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study. Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of endpoints. Results: S-ICD implant was attempted in 1116 patients and 1111 patients were included in post-implant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% women, 23.4% black race, 53.5% with ischemic heart disease, 87.7% with symptomatic heart failure and a mean LVEF of 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (Lower confidence limit LCL 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the three-incision technique, no history of atrial fibrillation, and ischemic etiology. The 18-month all cause shock free rate was 90.6% (LCL 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication free rate at 18 months was 92.7%. Conclusions: This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of co-morbidities in comparison to earlier S-ICD trials. The inappropriate shock rate (3.1% at one year) is the lowest reported for the S-ICD and lower than many TV ICD studies using contemporary programming to reduce IAS. Clinical Trial Registration: URL https://clinicaltrials.gov Unique Identifier NCT02433379
AimsThe recent American College of Cardiology and American Heart Association Guidelines on hypertrophic cardiomyopathy (HCM) have confirmed surgical myectomy as the gold standard for non-pharmacological treatment of obstructive HCM. However, during the last 15 years, an extensive use of alcohol septal ablation has led to the virtual extinction of myectomy programmes in several European countries. Therefore, many HCM candidates for myectomy in Europe cannot be offered the option of this procedure. The purpose of our study is to report the difficulties and results in developing a myectomy programme for HCM in a centre without previous experience with this procedure.Methods and resultsThe clinical course is reported of 124 consecutive patients with obstructive HCM and heart failure symptoms who underwent myectomy at a single European centre between 1996 and 2010. The median follow-up was 20.3 months (inter-quartile range: 3.9–40.6 months). No patients were lost to follow-up. A cumulative incidence of HCM-related death after myectomy was 0.8, 3.3, and 11.2% at 1, 5, and 10 years, respectively, including one operative death (procedural mortality 0.8%). The left ventricular (LV) outflow gradient decreased from 95 ± 36 mmHg before surgery to 12 ± 6 mmHg at most recent evaluation (P < 0.001), with none of the patients having a significant residual LV outflow gradient. Of the 97 patients in New York Heart Association functional class III–IV before surgery, 93 (96%) were in class I–II at most recent evaluation (P < 0.001).ConclusionOur results show that the development of a myectomy programme at a centre without previous experience with this procedure is feasible and can lead to highly favourable clinical results.
Background-Inherited cardiac arrhythmia susceptibility contributes to sudden death during infancy and may contribute to perinatal and neonatal mortality, but the molecular basis of this risk and the relationship to genetic disorders presenting later in life is unclear. We studied the functional and pharmacological properties of a novel de novo cardiac sodium channel gene (SCN5A) mutation associated with an extremely severe perinatal presentation of long-QT syndrome in unrelated probands of different ethnicity. Methods and Results-Two subjects exhibiting severe fetal and perinatal ventricular arrhythmias were screened for SCN5A mutations, and the functional properties of a novel missense mutation (G1631D) were determined by whole-cell patch clamp recording. In vitro electrophysiological studies revealed a profound defect in sodium channel function characterized by Ϸ10-fold slowing of inactivation, increased persistent current, slowing of recovery from inactivation, and depolarized voltage dependence of activation and inactivation. Single-channel recordings demonstrated increased frequency of late openings, prolonged mean open time, and increased latency to first opening for the mutant. Subjects carrying this mutation responded clinically to the combination of mexiletine with propranolol and survived. Pharmacologically, the mutant exhibited 2-fold greater tonic and use-dependent mexiletine block than wild-type channels. The mutant also exhibited enhanced tonic (2.4-fold) and use-dependent block (Ϸ5-fold) by propranolol, and we observed additive effects of the 2 drugs on the mutant. Conclusions-Our study demonstrates the molecular basis for a malignant perinatal presentation of long-QT syndrome, illustrates novel functional and pharmacological properties of SCN5A-G1631D, which caused the disorder, and reveals therapeutic benefits of propranolol block of mutant sodium channels in this setting. (Circ Arrhythmia Electrophysiol.
Select Secure is a promising system for selective-site pacing in children.
The above criteria enabled SHBP and PHP to be validated easily and clearly. A longer follow-up will be needed in order to ascertain whether the clinical outcome of these two approaches differs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.