MR imaging coupled with contrast material-enhanced dynamic MR imaging is highly accurate in local-regional staging of endometrial carcinoma; more challenging is the assessment of pelvic and lumboaortic lymph nodes.
An ultrasound examination was performed in 401 patients who had isotopically cold, solitary lesions of the thyroid gland. Of the parameters studied, the level of echoes was the most useful in making the sonographic diagnosis: the rate of malignancy was extremely low both in hyperechoic and echo-free lesions. The presence of a peripheral, complete "halo" appeared to be helpful in differentiating benign lesions from malignant lesions. Approximately 20-25% of the lesions thought to be solitary on the radionuclide study were found to be multinodular on US. When fine-needle aspiration biopsy was used with US the need for surgical exploration of the thyroid gland was obviated in selected cases.
The prevalence of musculoskeletal complaints of the hand and wrist, and the neck and back, in physicians who operate sonography equipment was evaluated, and associations between these complaints and various work-related and personal variables were studied. A questionnaire survey was distributed among physician sonographers (sonologists) in Italy. The relationship between work habits and musculoskeletal complaints was analyzed by logistic regression models adjusted for gender, age, and duration of work with ultrasound. A total of 2041 physician sonographers completed the questionnaire. It was found that a large proportion of the subjects regularly had work-related complaints, such as neck and back pain (NBP) (18.5%) or hand and wrist cumulative trauma disorder (HWD) (5.3%). Roughly 80% of the sonographers were currently affected, or had been affected in the past, by one or more work-related symptoms. Various work-related factors appeared to be related to musculoskeletal syndromes. The average time spent for each examination was related both to NBP and HWD. Discomfort for transducer design was the best predictor of HWD, whereas a comfortable chair and correct position of the body protected from the onset of NBP. These results support the role of ergonomic factors in the pathogenesis of both NBP and HWD in sonographers.
Objective. To describe the sonographic findings of distal biceps tendon ruptures and to assess the accuracy of the technique. Methods. Twenty-five patients with clinically indicated distal biceps tendon ruptures were prospectively studied by sonography. Five patients also underwent magnetic resonance imaging. Surgical confirmation was obtained in 14 patients. Results. Seventeen complete tendon ruptures and 3 partial tears were correctly shown by sonography; 1 complete rupture was incorrectly shown as a partial tear by sonography. Sonographic features of complete rupture were absence of tendon in the expected location, fluid collection in a typical tendon gap, and a mass in the antecubital fossa. Sonographic features of incomplete rupture were intratendinous hypoechogenicity and tendon thinning. Peritendinous fluid was found in complete and incomplete ruptures. Conclusions. In distal biceps tendon ruptures, sonography is a cost-effective method that can confirm the clinical indications with good accuracy and can show tendon lesions when the clinical indications are low.
In CHI patients, (18)F-DOPA PET or PET/CT demonstrated high sensitivity and specificity in differentiating between focal and diffuse CHI. (18)F-DOPA PET or PET/CT are accurate methods of localizing focal CHI. Nevertheless, possible sources of false-negative results for focal CHI should be kept in mind.
Radiologists and radiotherapists are exposed to major occupational stress factors, and a significant percentage of them suffer from workplace stress. A special effort is required to prevent this condition.
Objective: The aim of the study is to compare CT enterography with polyethylene glycol solution (PEG-CT) with CT enteroclysis (CT-E) in patients with suspected small bowel disease. Methods: 145 patients underwent abdominal contrast-enhanced 16-row multidetector CT after administration of 2000 ml of PEG by mouth (n575) or after administration of 2000 ml of methylcellulose by nasojejunal tube (n570). Small bowel distension, luminal and extraluminal findings were evaluated and compared with small bowel followthrough examination in 60 patients, double contrast enema in 50, surgery in 25 and endoscopy in 35. Statistical evaluation was carried out by x 2 testing. For both techniques we have also calculated the effective dose and the equivalent dose in a standard patient. Results: Crohn's disease was diagnosed in 64 patients, neoplasms in 16, adhesions in 6. Distension of the jejunum was better with CT-E than PEG-CT (p,0.05: statistically significant difference). No significant difference was present for others sites (p.0.05). Evaluation of pathological ileal loops was good with both techniques. The values of sensitivity, specificity and diagnostic accuracy were respectively 94%, 100% and 96% with CT-E, and 93%, 94% and 93% with PEG-CT. The effective dose for PEG-CT was less than the dose for the CT-E (34.7 mSv vs 39.91 mSv). Conclusion: PEG-CT shows findings of Crohn's disease as well as CT-E does, although CT-E gives better bowel distension, especially in the jejunum, and has higher specificity than PEG-CT.
The purpose of this study was to evaluate the diagnostic accuracy of multidetector-CT enteroclysis (MDCT-E) versus barium enteroclysis with methylcellulose (BE) in clinically selected patients with suspected small bowel disease. We prospectively studied 52 patients who underwent unenhanced and contrast-enhanced multidetector CT (16 rows) after administration of 2-2.5 l of methylcellulose by naso-jejunal tube. BE was performed after administration of barium 60% w/v (200-250 ml) and methylcellulose (1-2 l). Patients with radiological signs of Crohn's disease were classified into the following subtypes: active, fibrostenotic, fistulising/perforating, reparative or regenerative subtypes. Twenty-eight patients also underwent endoscopy. The radiological prevalent subtype was the active subtype. The sensitivity, specificity and diagnostic accuracy of MDCT-E versus BE was 83%, 100% and 89%, respectively. BE showed five false negative CT cases due to early Crohn's disease; endoscopy confirmed positive cases of the CT and the BE, but showed one false negative case of the BE. Together, MDCT enteroclysis and BE permitted the diagnosis of Crohn's disease in 30 patients, adhesions in one patient, lymphoma in two patients and carcinoid tumours in two patients. In conclusion, MDCT-E permits good representation of pathological patterns. Early stages of Crohn's disease are better evaluated by BE.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.