Charge variants, especially acidic charge variants, in recombinant monoclonal antibodies are critical quality attributes, which can affect antibodies' properties in vitro and in vivo. Meanwhile, charge variants are cumulative effects of various post-translational modifications and chemical degradations on antibody. In this work, to investigate the effect of lowering culture pH in the stationary phase on acidic charge variant contents in fed-batch cultures and its mechanism, cell culture experiments in 2-L bioreactors were firstly performed to explore the changes in the charge distribution under the pH downshift condition using weak cation exchange chromatography. It is found that acidic charge variant contents were significantly decreased by pH downshift. Then, to reveal the mechanism by which the content of acidic charge variants is reduced under pH downshift condition, the variation of post-translational modifications and chemical degradations under the pH downshift condition was explored. Meanwhile, the structure of the acidic charge variants was characterized. Several analysis experiments including size exclusion chromatography, capillary electrophoresis-sodium dodecyl sulfate under non-reducing conditions, tryptic peptide map, and reduced antibody mass were applied in this study. The results show that the mechanism by which the content of acidic charge variants is reduced is that the contents of disulfide bond reduction, galactosylation, and asparagine deamination of the HC-N388 in the Fc domain were reduced by pH downshift.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.