We report a case of a fistula between the vertebral artery and the internal jugular vein that occurred after the erroneous placement of a central venous catheter. The patient was presented with tinnitus. Endovascular treatment with a balloon expandable covered stent placed into the vertebral artery was performed. One year follow-up showed satisfactory exclusion of the fistula, patency of the stented vertebral artery, and resolution of the symptoms. Only few other similar cases are reported in the literature with the use of different types of stents.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.