We conducted a 31-month retrospective review of all laboratory-confirmed Streptococcus suis infections admitted to public hospitals in Hong Kong. Strain identification, serotyping and antibiotic susceptibility tests were conducted on S. suis isolates. Twenty-one sporadic cases were identified, comprising 18 (86%) males and 3 (14%) females. About half were patients aged 65 years. More cases occurred during summer. Occupational exposure was documented in five (24%) cases. The estimated annual incidence was 0.09/100 000 in the general population and 32/100 000 in people with occupational exposure to pigs and raw pork. The primary clinical manifestations were meningitis (48%), septicaemia (38%) and endocarditis (14%). The case-fatality rate was 5%. All available isolates from 15 patients were serotype 2, sensitive to penicillin, ampicillin, ceftriaxone, but resistant to tetracycline. Injury prevention and proper handling of pigs or raw pork should be advocated to both at-risk occupational groups and the general population.
To assess the diagnostic and operational performance of the InBiOS AMD rapid diagnostic test (RDT) (Seattle, USA) for the detection of B. pseudomallei in grown blood culture broth. The InBiOS RDT is a lateral flow immunoassay in a strip format detecting B. pseudomallei capsular polysaccharide in culture fluids, marketed for research only. Broth of blood culture bottles (BacT/Alert, bioMérieux, Marcy L’Etoile, France) sampled in adult patients at the Sihanouk Hospital Center of HOPE, Phnom Penh, Cambodia, during 2010–2017 and stored at − 80 °C was tested. They included samples grown with B. pseudomallei (n = 114), samples with no growth (n = 12), and samples with growth of other pathogens (n = 139, among which Burkholderia cepacia (n = 5)). Diagnostic sensitivity and specificity were 96.5% [95% confidence interval (CI): 91.3–98.6%] and 100% [CI: 97.5–100%] respectively. Background clearance and line intensities were good and very good. The RDT’s test strip, not housed in a cassette, caused difficulties in manipulation and biosafety. The centrifugation step prescribed by the procedure challenged biosafety, but processing of 19 B. pseudomallei samples without centrifugation showed similar results for line intensity and background clearance, compared to centrifugation. The InBiOS RDT showed excellent accuracy for detection of B. pseudomallei in grown blood culture broth. Provided operational adaptations such as cassette housing, it has the potential to reduce time to diagnosis of melioidosis.Electronic supplementary materialThe online version of this article (10.1007/s10096-018-3237-3) contains supplementary material, which is available to authorized users.
BackgroundIn low resource settings, Salmonella serovars frequently cause bloodstream infections. This study investigated the diagnostic performance of immunochromatographic rapid diagnostic tests (RDTs), which detect Salmonella antigens, when applied to stored grown blood culture broth.Material/MethodsThe SD Bioline One Step Salmonella Typhi Ag Rapid Detection Kit (Standard Diagnostics, Republic of Korea), marketed for the detection of Salmonella enterica serovar Typhi (Salmonella Typhi) in stool and the Salmonella Ag Rapid Test (Creative Diagnostics, USA), marketed for the detection of all Salmonella serotypes in stool, were selected for evaluation based on a pre-test evaluation of six RDT products. The limits of detection (LOD) for culture suspensions were established and the selected RDT products were assessed on 19 freshly grown spiked blood culture broth samples and 413 stored clinical blood culture broth samples, collected in Cambodia and the Democratic Republic of the Congo.ResultsThe LOD of both products was established as 107−108 CFU/ml. When applied to clinical blood culture broth samples, the diagnostic sensitivity and specificity of the SD Bioline RDT were respectively 100% and 79.7% for the detection of Salmonella Typhi; 94.4% (65/69) of false-positive results were caused by Salmonella Enteritidis. When considering the combined detection of Salmonella Typhi and Enteritidis (both group D Salmonella), sensitivity and specificity were 97.9% and 98.5% respectively. For Creative Diagnostics, diagnostic sensitivity was 78.3% and specificity 91.0% for all Salmonella serotypes combined; 88.3% (53/60) of false negative results were caused by Salmonella Paratyphi A.ConclusionsWhen applied to grown blood culture broths, the SD Bioline RDT had a good sensitivity and specificity for the detection of Salmonella Typhi and Salmonella Enteritidis. The Creative Diagnostics product had a moderate sensitivity and acceptable specificity for the detection of all Salmonella serovars combined and needs further optimization. A RDT that reliably detects Salmonella Paratyphi A is needed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.