The results reveal certain aspects that may affect the success of speech imagery classification from EEG signals, such as sound, meaning and word complexity. This can potentially extend the capability of utilizing speech imagery in future BCI applications. The dataset of speech imagery collected from total 15 subjects is also published.
One of the hottest topics in rehabilitation robotics is that of proper control of prosthetic devices. Despite decades of research, the state of the art is dramatically behind the expectations. To shed light on this issue, in June, 2013 the first international workshop on Present and future of non-invasive peripheral nervous system (PNS)–Machine Interfaces (MI; PMI) was convened, hosted by the International Conference on Rehabilitation Robotics. The keyword PMI has been selected to denote human–machine interfaces targeted at the limb-deficient, mainly upper-limb amputees, dealing with signals gathered from the PNS in a non-invasive way, that is, from the surface of the residuum. The workshop was intended to provide an overview of the state of the art and future perspectives of such interfaces; this paper represents is a collection of opinions expressed by each and every researcher/group involved in it.
As robots come closer to humans, an efficient human-robotcontrol interface is an utmost necessity. In this paper, electromyographic (EMG) signals from muscles of the human upper limb are used as the control interface between the user and a robot arm. A mathematical model is trained to decode upper limb motion from EMG recordings, using a dimensionality-reduction technique that represents muscle synergies and motion primitives. It is shown that a 2-D embedding of muscle activations can be decoded to a continuous profile of arm motion representation in the 3-D Cartesian space, embedded in a 2-D space. The system is used for the continuous control of a robot arm, using only EMG signals from the upper limb. The accuracy of the method is assessed through real-time experiments, including random arm motions.
Myoelectric control is filled with potential to significantly change human-robot interaction due to the ability to non-invasively measure human motion intent. However, current control schemes have struggled to achieve the robust performance that is necessary for use in commercial applications. As demands in myoelectric control trend toward simultaneous multifunctional control, multi-muscle coordinations, or synergies, play larger roles in the success of the control scheme. Detecting and refining patterns in muscle activations robust to the high variance and transient changes associated with surface electromyography is essential for efficient, user-friendly control. This article reviews the role of muscle synergies in myoelectric control schemes by dissecting each component of the scheme with respect to associated challenges for achieving robust simultaneous control of myoelectric interfaces. Electromyography recording details, signal feature extraction, pattern recognition and motor learning based control schemes are considered, and future directions are proposed as steps toward fulfilling the potential of myoelectric control in clinically and commercially viable applications.
Myoelectric control offers a direct interface between human intent and various robotic applications through recorded muscle activity. Traditional control schemes realize this interface through direct mapping or pattern recognition techniques. The former approach provides reliable control at the expense of functionality, while the latter increases functionality at the expense of long-term reliability. An alternative approach, using concepts of motor learning, provides session-independent simultaneous control, but previously relied on consistent electrode placement over biomechanically independent muscles. This paper extends the functionality and practicality of the motor learning-based approach, using high-density electrode grids and muscle synergy-inspired decomposition to generate control inputs with reduced constraints on electrode placement. The method is demonstrated via real-time simultaneous and proportional control of a 4-DoF myoelectric interface over multiple days. Subjects showed learning trends consistent with typical motor skill learning without requiring any retraining or recalibration between sessions. Moreover, they adjusted to physical constraints of a robot arm after learning the control in a constraint-free virtual interface, demonstrating robust control as they performed precision tasks. The results demonstrate the efficacy of the proposed man-machine interface as a viable alternative to conventional control schemes for myoelectric interfaces designed for long-term use.
Stroke affects one out of every six people on Earth. Approximately 90% of stroke survivors have some functional disability with mobility being a major impairment, which not only affects important daily activities but also increases the likelihood of falling. Originally intended to supplement traditional post-stroke gait rehabilitation, robotic systems have gained remarkable attention in recent years as a tool to decrease the strain on physical therapists while increasing the precision and repeatability of the therapy. While some of the current methods for robot-assisted rehabilitation have had many positive and promising outcomes, there is moderate evidence of improvement in walking and motor recovery using robotic devices compared to traditional practice. In order to better understand how and where robot-assisted rehabilitation has been effective, it is imperative to identify the main schools of thought that have prevailed. This review intends to observe those perspectives through three different lenses: the goal and type of interaction, the physical implementation, and the sensorimotor pathways targeted by robotic devices. The ways that researchers approach the problem of restoring gait function are grouped together in an intuitive way. Seeing robot-assisted rehabilitation in this unique light can naturally provoke the development of new directions to potentially fill the current research gaps and eventually discover more effective ways to provide therapy. In particular, the idea of utilizing the human inter-limb coordination mechanisms is brought up as an especially promising area for rehabilitation and is extensively discussed.
Human-robot control interfaces have received increased attention during the last decades. These interfaces increasingly use signals coming directly from humans since there is a strong necessity for simple and natural control interfaces. In this paper, electromyographic (EMG) signals from the muscles of the human upper limb are used as the control interface between the user and a robot arm. A switching regime model is used to decode the EMG activity of 11 muscles to a continuous representation of arm motion in the 3-D space. The switching regime model is used to overcome the main difficulties of the EMG-based control systems, i.e., the nonlinearity of the relationship between the EMG recordings and the arm motion, as well as the nonstationarity of EMG signals with respect to time. The proposed interface allows the user to control in real time an anthropomorphic robot arm in the 3-D space. The efficiency of the method is assessed through real-time experiments of four persons performing random arm motions.
Human-robot control interfaces have received increased attention during the past decades. With the introduction of robots in everyday life, especially in providing services to people with special needs (i.e., elderly, people with impairments, or people with disabilities), there is a strong necessity for simple and natural control interfaces. In this paper, electromyographic (EMG) signals from muscles of the human upper limb are used as the control interface between the user and a robot arm. EMG signals are recorded using surface EMG electrodes placed on the user's skin, making the user's upper limb free of bulky interface sensors or machinery usually found in conventional human-controlled systems. The proposed interface allows the user to control in real time an anthropomorphic robot arm in 3-D space, using upper limb motion estimates based only on EMG recordings. Moreover, the proposed interface is robust to EMG changes with respect to time, mainly caused by muscle fatigue or adjustments of contraction level. The efficiency of the method is assessed through real-time experiments, including random arm motions in the 3-D space with variable hand speed profiles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.