Objective
This study aimed to assess the characteristics of different designs of systematic reviews (SRs) registered in the International Prospective Register of Systematic Reviews (PROSPERO) about COVID‐19.
Methods
The search was performed in the PROSPERO database using the strategy proposed by the database and considered only human studies. The last date of the search was April 27, 2020. Full text of all records was accessed, and data were extracted by a single researcher, which was further double‐checked by another researcher. A descriptive analysis was performed considering record characteristics using tables.
Results
We included 564 records from which the vast majority were registered as SRs (n = 513, 91%). In general, we found poor reporting and missing or confusing information, since 84% of the records (n = 474) did not report the full search that would be adopted, 16% (n = 90) did not report clearly the databases that would be used, and 49.1% (n = 277) did not report the number of primary outcomes. The main focus of most of the records involved clinical, epidemiological, complication, and laboratory characteristics (n = 173, 30.7%) or the treatment of COVID‐19 (n = 138, 24.5%).
Conclusion
A large number of SRs about COVID‐19 have been conducted, and many of the assessed records were poorly reported and would be difficult to replicate. Besides, collected data points to an epidemic of redundant reviews on COVID‐19.
Purpose: To evaluate the influence of quantity and positioning of veneered zirconia specimens during firing of porcelain on their fatigue performance and colorimetric differences. Methods: Bilayer discs (Ø=15 mm) were made, following ISO 6872 guidelines, using a Y-TZP core (yttria-stabilized tetragonal zirconia polycrystal ceramic; VITA In-Ceram YZ) and a feldspathic veneering material (VITA VM9), being both layers with 0.7 mm thickness. Y-TZP discs were sintered, the veneering material was applied over it, and the bilayer specimens were fired according to two factors (n=20): 'quantity' (1 or 5 samples per firing cycle; G1 and G5 groups respectively) and 'positioning' of the specimens inside the furnace (center or periphery of the refractory tray; G5C and G5P groups, respectively). The CIEL*a*b* parameters were recorded with a spectrophotometer and the color difference (ΔE 00) and translucency (TP 00) were calculated using CIEDE2000 equations. The step-stress fatigue test was performed with the veneer facing down (region of tensile stress concentration), 10 Hz frequency, initial tension of 20 MPa for 5,000 cycles, followed by steps of 10,000 cycles using a step size of 10 MPa, up to 100 MPa; data from strength and number of cycles for failure were recorded for statistical analysis. Results: Unacceptable color differences (ΔE 00 >1.8) were observed comparing G5C vs. G1 (quantity) and G5C vs. G5P (positioning), meanwhile translucency parameters were not affected. Besides, only the 'quantity' factor influenced the fatigue performance (G1>G5C). None of the tested specimens survived beyond 90N and/or 75000 cycles. Conclusions: The quantity and position of the specimens during firing influence the final color of porcelain-veneered zirconia, and firing one specimen per cycle improved the fatigue performance of the bilayer system.
The aim of this study was to evaluate and compare the stress concentration of short dental implants supporting different conical abutments using 3D finite element analysis (3D-FEA). A tridimensional model of single-unit short dental implants (5.2 mm × 5 mm) was designed using the computer-aided design (CAD) software based on the manufacturer’s stereolithography. The short implants were positioned in a bone model to support titanium or ceramic-reinforced PEEK conical abutments considering different bone levels (supra-crestal, crestal or sub-crestal). With the aid of a computer-aided engineering (CAE) software, the finite element model was created and an axial load of 500 N was applied. Observing the mechanical response of the implant, abutment and screw, both evaluated materials resulted in homogeneous stress and could be indicated for implant-supported restorations with short fixtures. However, aiming to decrease the strain in the bone tissue, placing the implant in the sub-crestal position is a preferable option; while the supra-crestal placement decreases the stress at the screw and implant.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.