The formation of the ophthalmic artery (OA) is a complex process with two different proposed embryological steps for its development. Several anatomical variants have been described. We present a very unusual origin of the ophthalmic artery from the basilar trunk, in a 45-year-old male with a history of pontine hemorrhagic stroke. MRI and CTA showed evidence of previous hemorrhage in the pons and several intracranial arterial dysplastic dilatations. DSA confirmed several fusiform dilatations of the basilar trunk. In the left ICA, no ophthalmic artery was seen arising from the carotid siphon. The left ophthalmic artery arises from the basilar trunk and runs lateral to the cavernous sinus through the middle cranial fossa, entering the left orbit at the superior orbital fissure. The patient was treated conservatively. Two main theories for this anomaly are known, one from Lasjaunias and the other from Paget. To our knowledge, this basilar origin of the OA has only been described three times in the literature. For its origin, we propose a partial persistence of the trigeminal artery together with a dominance of the dorsal ophthalmic artery.
BackgroundAneurysm recurrence remains a challenge when coiling cerebral aneurysms. Development of next generation coils has focused on accelerating thrombus maturation and increasing coil packing density. Ultra low density shape memory polymer is a novel embolic material designed for this purpose. The polymer is crimped over a platinum–tungsten coil for catheter delivery and self-expands to a predefined volume on contact with blood.MethodsThis prospective study in humans evaluated aneurysms 5–16 mm (inclusive) in diameter that were indicated for endovascular coil embolization. At least 70% coil volume was required to be shape memory polymer coils. Patients were followed-up according to standard of care for 12 months.ResultsNine patients (89% women, mean age 55.8±11.7 years) were treated with shape memory polymer coils and completed 12 months of follow-up. Aneurysms were all unruptured and were in the ophthalmic segment of the internal carotid artery (n=7), posterior communicating artery, and anterior cerebral artery A1–A2 segment. Aneurysms were a mean of 7.8±2.9 mm in diameter (range 5.2–14.9 mm). The mean packing density based on unexpanded polymer was 17±6%. Packing density based on expanded polymer was 43±13%. At 12 months, no recurrence had occurred, and a Raymond–Roy occlusion classification of 1 (n=5) or 2 (n=4) was observed. No serious adverse events related to the study device occurred over the 12 months after the procedure.ConclusionsShape memory polymer coils were safe and effective in treating intracranial aneurysms over 12 months in this first study in human subjects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.