CSHI safely brought ACTH and cortisol toward normal circadian levels without adversely affecting glucocorticoid metabolism in the way that OHC did. Positive effects on HRQoL were noted with CSHI, indicating that physiological glucocorticoid replacement therapy may be beneficial and that CSHI might become a treatment option for patients poorly controlled on conventional therapy.
Objective: Because we found higher serum 25-hydroxyvitamin D (25(OH)D) levels among smokers than among non-smokers with analyses using an electrochemiluminescence immunoassay (ECLIA) from Roche, the purpose of the present study was to examine whether this difference between smokers and non-smokers was maintained using other serum 25(OH)D assays. Design: A cross-sectional population-based study on 6932 participants from the Tromsø study, 1994-1995, and one validation study comparing six different serum 25(OH)D assays in 53 non-smokers and 54 smokers were performed. Methods: The association between smoking, season and serum 25(OH)D as measured by ECLIA (Roche) was assessed in the population-based study using general linear models with multivariate adjustments. In the validation study, serum levels of 25(OH)D were analysed with liquid chromatography coupled with mass spectrometry assay from two different laboratories, RIA (DiaSorin), HPLC, RIA (IDS) and ECLIA (Roche). T-tests and linear mixed model analyses were performed to compare the serum 25(OH)D levels in smokers and non-smokers within and between the methods. Results: In the population-based study, the serum levels of 25(OH)D using the ECLIA method were 51.9, 53.2 and 72.0 nmol/l in never, former and current smokers (P!0.01). In the validation study, the serum concentration of 25(OH)D was 10.3 nmol/l higher in smokers than in non-smokers (P!0.01) using the ECLIA (Roche), while non-significantly lower serum levels of 25(OH)D were found in smokers using the other five methods. Conclusions: These two studies indicate that the ECLIA (Roche) overestimates serum 25(OH)D levels in smokers by unknown mechanisms. If confirmed, this might have clinical consequences, and the issue needs further exploration.
ObjectiveLiquid chromatography–tandem mass spectrometry (LC–MS/MS) offers superior analytical specificity compared with immunoassays, but it is not available in many regions and hospitals due to expensive instrumentation and tedious sample preparation. Thus, we developed an automated, high-throughput LC–MS/MS assay for simultaneous quantification of ten endogenous and synthetic steroids targeting diseases of the hypothalamic–pituitary–adrenal axis and gonads.MethodsDeuterated internal standards were added to 85 μl serum and processed by liquid–liquid extraction. Cortisol, cortisone, prednisolone, prednisone, 11-deoxycortisol, dexamethasone, testosterone, androstenedione and progesterone were resolved by ultra-high-pressure chromatography on a reversed-phase column in 6.1 min and detected by triple-quadrupole mass spectrometry. The method was used to assess steroid profiles in women with Addison's disease (AD, n=156) and blood donors (BDs, n=102).ResultsPrecisions ranged from 4.5 to 10.1% relative standard deviations (RSD), accuracies from 95 to 108% and extraction recoveries from 60 to 84%. The method was practically free of matrix effects and robust to individual differences in serum composition. Most postmenopausal AD women had extremely low androstenedione concentrations, below 0.14 nmol/l, and median testosterone concentrations of 0.15 nmol/l (interquartile range 0.00–0.41), considerably lower than those of postmenopausal BDs (1.28 nmol/l (0.96–1.64) and 0.65 nmol/l (0.56–1.10) respectively). AD women in fertile years had androstenedione concentrations of 1.18 nmol/l (0.71–1.76) and testosterone concentrations of 0.44 nmol/l (0.22–0.63), approximately half of those found in BDs of corresponding age.ConclusionThis LC–MS/MS assay provides highly sensitive and specific assessments of glucocorticoids and androgens with low sample volumes and is suitable for endocrine laboratories and research. Its utility has been demonstrated in a large cohort of women with AD, and the data suggest that women with AD are particularly androgen deficient after menopause.
Simultaneous measurement of serum DXM and cortisol reduced false-positive DSTs by 20% and improved the specificity. S-DXM >3.3 nmol/L is sufficient for the suppression of cortisol <50 nmol/L. Measurement of glucocorticoids in saliva is a non-invasive and easy procedure and post-DST sa-cortisone was found particularly useful in the diagnosis of CS.
LC-MS/MS provides cutoff levels for cortisol and 17-OHP after cosyntropin stimulation that are lower than those based on immunoassays, possibly because cross-reactivity between steroid intermediates and cortisol is eliminated. This reduces the number of false-positive tests for AI and false-negative tests for NCCAH.
Laterality of ACS does not always correspond to findings on CT images. AVS is a safe and valuable tool for differentiation between unilateral and bilateral cortisol secretion and should be considered when operative treatment of ACS is a possibility.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.