Over the last decade, the introduction of microarray technology has had a profound impact on gene expression research. The publication of studies with dissimilar or altogether contradictory results, obtained using different microarray platforms to analyze identical RNA samples, has raised concerns about the reliability of this technology. The MicroArray Quality Control (MAQC) project was initiated to address these concerns, as well as other performance and data analysis issues. Expression data on four titration pools from two distinct reference RNA samples were generated at multiple test sites using a variety of microarray-based and alternative technology platforms. Here we describe the experimental design and probe mapping efforts behind the MAQC project. We show intraplatform consistency across test sites as well as a high level of interplatform concordance in terms of genes identified as differentially expressed. This study provides a resource that represents an important first step toward establishing a framework for the use of microarrays in clinical and regulatory settings.
Stem cell response to a library of scaffolds with varied 3D structures was investigated. Microarray screening revealed that each type of scaffold structure induced a unique gene expression signature in primary human bone marrow stromal cells (hBMSCs). Hierarchical cluster analysis showed that treatments sorted by scaffold structure and not by polymer chemistry suggesting that scaffold structure was more influential than scaffold composition. Further, the effects of scaffold structure on hBMSC function were mediated by cell shape. Of all the scaffolds tested, only scaffolds with a nanofibrous morphology were able to drive the hBMSCs down an osteogenic lineage in the absence of osteogenic supplements. Nanofiber scaffolds forced the hBMSCs to assume an elongated, highly branched morphology. This same morphology was seen in osteogenic controls where hBMSCs were cultured on flat polymer films in the presence of osteogenic supplements (OS). In contrast, hBMSCs cultured on flat polymer films in the absence of OS assumed a more rounded and less-branched morphology. These results indicate that cells are more sensitive to scaffold structure than previously appreciated and suggest that scaffold efficacy can be optimized by tailoring the scaffold structure to force cells into morphologies that direct them to differentiate down the desired lineage.
We have assessed the utility of RNA titration samples for evaluating microarray platform performance and the impact of different normalization methods on the results obtained. As part of the MicroArray Quality Control project, we investigated the performance of five commercial microarray platforms using two independent RNA samples and two titration mixtures of these samples. Focusing on 12,091 genes common across all platforms, we determined the ability of each platform to detect the correct titration response across the samples. Global deviations from the response predicted by the titration ratios were observed. These differences could be explained by variations in relative amounts of messenger RNA as a fraction of total RNA between the two independent samples. Overall, both the qualitative and quantitative correspondence across platforms was high. In summary, titration samples may be regarded as a valuable tool, not only for assessing microarray platform performance and different analysis methods, but also for determining some underlying biological features of the samples.
There is a critical need for standard approaches to assess, report and compare the technical performance of genome-scale differential gene expression experiments. Here we assess technical performance with a proposed standard 'dashboard' of metrics derived from analysis of external spike-in RNA control ratio mixtures. These control ratio mixtures with defined abundance ratios enable assessment of diagnostic performance of differentially expressed transcript lists, limit of detection of ratio (LODR) estimates and expression ratio variability and measurement bias. The performance metrics suite is applicable to analysis of a typical experiment, and here we also apply these metrics to evaluate technical performance among laboratories. An interlaboratory study using identical samples shared among 12 laboratories with three different measurement processes demonstrates generally consistent diagnostic power across 11 laboratories. Ratio measurement variability and bias are also comparable among laboratories for the same measurement process. We observe different biases for measurement processes using different mRNA-enrichment protocols.
Background: The interpretability of microarray data can be affected by sample quality. To systematically explore how RNA quality affects microarray assay performance, a set of rat liver RNA samples with a progressive change in RNA integrity was generated by thawing frozen tissue or by ex vivo incubation of fresh tissue over a time course.
Within the International Life Sciences Institute Committee on Genomics, a working group was formed to focus on the application of microarray technology to preclinical assessments of druginduced nephrotoxicity. As part of this effort, Sprague-Dawley rats were treated with the nephrotoxicant cisplatin at doses of 0.3-5 mg/kg over a 4-to 144-hr time course. RNA prepared from these animals was run on a variety of microarray formats at multiple sites. A set of 93 differentially expressed genes associated with cisplatin-induced renal injury was identified on the National Institute of Environmental Health Sciences (NIEHS) custom cDNA microarray platform using quadruplicate measurements of pooled animal RNA. The reproducibility of this profile of statistically significant gene changes on other platforms, in pooled and individual animal replicate samples, and in an independent study was investigated. A good correlation in response between platforms was found among the 48 genes in the NIEHS data set that could be matched to probes on the Affymetrix RGU34A array by UniGene identifier or sequence alignment. Similar results were obtained with genes that could be linked between the NIEHS and Incyte or PHASE-1 arrays. The degree of renal damage induced by cisplatin in individual animals was commensurate with the number of differentially expressed genes in this data set. These results suggest that gene profiles linked to specific types of tissue injury or mechanisms of toxicity and identified in wellperformed replicated microarray experiments may be extrapolatable across platform technologies, laboratories, and in-life studies.
The donor photobleaching method (T. M. Jovin and D. J. Arndt-Jovin. 1989. Annu. Rev. Biophys. Biophys. Chem. 18:271-308.) has been adapted to an ACAS 570 (laser scanning microscope) system to measure fluorescence resonance energy transfer (FRET) on individual human peripheral blood T cells. Photobleaching was completed in approximately 100 ms in our case and it followed double-exponential kinetics. The energy transfer efficiency (E) was approximately 20% between the CD4 epitopes OKT4-FITC and Leu-3a-PE as well as between OKT4E-FITC and OKT4-PE. E was approximately 8% between OKT4-FITC and Leu-4-PE (alpha CD3) and barely detectable (approximately 4%) from OKT4-FITC to Leu-5b-PE (alpha CD2). The E values obtained by the photobleaching method were highly reproducible both in repeated measurement of identical samples and in experiments with different batches of cells and were in agreement with the flow cytometric donor quenching measurements. As expected, E measured between primary and secondary layers of antibodies increased (from approximately 14% to approximately 28%) when F(ab')2 fragments were substituted for whole antibody molecules as the donor. On a T cell line we mapped the distance between the idiotypic determinant of the T cell receptor (TcR) and the Leu-4 epitope of CD3 as proximal as E = 28%, as compared to E = 4% between a framework TcR epitope and Leu-4. In the latter case, however, approximately 40% less Leu-4 was bound suggesting that the antigen binding site of TcR is in close proximity with one of the two CD3 epsilon chains, which hence are not equivalent.
The comparability and reliability of data generated using microarray technology would be enhanced by use of a common set of standards that allow accuracy, reproducibility and dynamic range assessments on multiple formats. We designed and tested a complex biological reagent for performance measurements on three commercial oligonucleotide array formats that differ in probe design and signal measurement methodology. The reagent is a set of two mixtures with different proportions of RNA for each of four rat tissues (brain, liver, kidney and testes). The design provides four known ratio measurements of >200 reference probes, which were chosen for their tissue-selectivity, dynamic range coverage and alignment to the same exemplar transcript sequence across all three platforms. The data generated from testing three biological replicates of the reagent at eight laboratories on three array formats provides a benchmark set for both laboratory and data processing performance assessments. Close agreement with target ratios adjusted for sample complexity was achieved on all platforms and low variance was observed among platforms, replicates and sites. The mixed tissue design produces a reagent with known gene expression changes within a complex sample and can serve as a paradigm for performance standards for microarrays that target other species.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.