Objective-To determine the acute injury profile in each of six sports and compare the injury rates between the sports.Design-Analysis of national sports injury insurance registry data.Setting-Finland during 1987-91.
During 1982, 118 patients with clavicular fracture were treated in the Department of Orthopaedics and Traumatology, Helsinki University Central Hospital. Eighty-nine patients appeared for the follow-up examination in 1984. Eighty-three fractures were treated with immobilization in a sling. Four fractures were treated with plate fixation primarily and two patients were operated on for delayed union. The immobilization averaged 21 days, range 10-42 days. The follow-up was 2 years in all cases. The result was good in 65 cases, satisfactory in 20, and poor in 4 cases. Patients with primary dislocation of more than 15 mm or with shortening observed at the follow-up examination had statistically significantly more pain than patients without these findings.
A group of 109 patients with unilateral low back pain for over three months were randomised to receive one of three types of injection treatment: cortisone and local anaesthetic injected into two facet joints (28), the same mixture around two facet joints (39), or physiological saline into two facet joints (42). The effect of the treatment was evaluated in relation to work attendance, pain, disability and movements of the lumbar spine. Patients were examined one hour and two and six weeks after treatment and also completed a questionnaire after three months.
W e analysed the complications encountered in 102 consecutive patients who had posterolateral lumbosacral fusion performed with transpedicular screw and rod fixation for non-traumatic disorders after a minimum of two years. Of these, 40 had spondylolysis and spondylolisthesis, 42 a degenerative disorder, 14 instability after previous laminectomy and decompression, and six pain after nonunion of previous attempts at spinal fusion without internal fixation. There were 75 multilevel and 27 single-level fusions. There were 76 individual complications in 48 patients, and none in the other 54. The complications seen were screw misplacement, coupling failure of the device, wound infection, nonunion, permanent neural injury, and loosening, bending and breakage of screws. Screw breakage or loosening was more common in patients with multilevel fusions (p < 0.001). Screws of 5 mm diameter should not be used for sacral fixation. Forty-six patients had at least one further operation for one or several complications, including 20 fusion procedures for nonunion. The high incidence of complications is a disadvantage of this technicallydemanding method.
In type-II fractures of the odontoid process, the treatment is either conservative in a halo vest or primary surgical stabilisation. Since nonunion, requiring prolonged immobilisation or late surgery, is common in patients treated in a halo vest, the identification of those in whom this treatment is likely to fail is important. We reviewed the data of 69 patients with acute type-II fractures of the odontoid process treated in a halo vest. The mean follow-up was 12 months. Conservative treatment was successful, resulting in bony union in 32 (46%) patients. Anterior dislocation, gender and age were unrelated to nonunion. However, nonunion did correlate with a fracture gap (> 1 mm), posterior displacement (> 5 mm), delayed start of treatment (> 4 days) and posterior redisplacement (> 2 mm). We conclude that patients presenting with these risk factors are unlikely to achieve bony union by treatment in a halo vest. They deserve careful attention during the follow-up period and should also be considered as candidates for primary surgical stabilisation.
We analysed the complications encountered in 102 consecutive patients who had posterolateral lumbosacral fusion performed with transpedicular screw and rod fixation for non-traumatic disorders after a minimum of two years. Of these, 40 had spondylolysis and spondylolisthesis, 42 a degenerative disorder, 14 instability after previous laminectomy and decompression, and six pain after nonunion of previous attempts at spinal fusion without internal fixation. There were 75 multilevel and 27 single-level fusions. There were 76 individual complications in 48 patients, and none in the other 54. The complications seen were screw misplacement, coupling failure of the device, wound infection, nonunion, permanent neural injury, and loosening, bending and breakage of screws. Screw breakage or loosening was more common in patients with multilevel fusions (p < 0.001). Screws of 5 mm diameter should not be used for sacral fixation. Forty-six patients had at least one further operation for one or several complications, including 20 fusion procedures for nonunion. The high incidence of complications is a disadvantage of this technically-demanding method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.