The digit current margins of a DRO magnetic film memory are determined by the disturb and writing or restoring thresholds. In an actual memory these thresholds will vary with both the film parameters and the drive line configuration. The effect of the magnetic parameters of the storage elements on these thresholds is determined by measuring the digit current margins of storage element arrays of varied magnetic parameters in a test apparatus simulating the memory operations and drive line configuration. A figure of merit calculated from these margin measurements is introduced and is used to determine the optimum film parameter values. To illustrate the effectiveness of the technique, data obtained during the experimental determination of optimum array coercivity are presented and the resultant figure of merit is discussed. Results indicate that array coercivities of 2.5 to 2.6 Oe yield maximum digit current margins. Interpretation of results of restore current measurements in terms of skew and dispersion currents is also presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.