Abstract-We have obtained interfacial properties of Galinstan, a nontoxic liquid-metal alloy, to help replace mercury in miniature devices. To prevent formation of an oxide skin that severely hinders the fluidic behavior of small Galinstan droplets and leads to inaccurate property data, we performed our experiments in a nitrogen-filled glove box. It was found that only if never exposed to oxygen levels above 1 part per million (ppm) would Galinstan droplets behave like a liquid. Two key properties were then investigated: contact angles and surface tension. Advancing and receding contact angles of Galinstan were measured from sessile droplets on various materials: for example, 146.8• and 121.5• , respectively, on glass. Surface tension was measured by the pendant-drop method to be 534.6 ± 10.7 mN/m. All the measurements were done in nitrogen at 28• C with oxygen and moisture levels below 0.5 ppm. To help design droplet-based microfluidic devices, we tested the response of Galinstan to electrowetting-on-dielectric actuation.[2011-0124]
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.