The effect of terbutaline infusion was studied in six patients with cardiogenic shock due to acute myocardial infarction. Terbutaline was initiated at 3 micrograms/kg/min, and the subsequent infusion rate was adjusted according to heart rate and blood pressure. At 3 hours after infusion arterial pressure increased from 62 +/- 13 mm Hg (mean +/- S.D.) to 89 +/- 13 mm Hg (P less than 0.001), cardiac index increased from 1.38 +/- 0.29 liter/min/m2 to 2.68 +/- 0.47 liter/min/m2 (P less than 0.001), and heart rate increased from 92 +/- 32 beats/min to 112 +/- 29 beats/min (P less than 0.005). Pulmonary artery wedge pressure fell from 24 +/- 7 mm Hg to 17 +/- 3 mm Hg (P less than 0.01), right atrial pressure fell from 12 +/- 4 mm Hg to 6 +/- 3 mm Hg (P less than 0.005), and systemic vascular resistance fell from 1880 +/- 641 dyn-sec/cm5 to 1515 +/- 418 dyn-sec/cm5 (P less than 0.05). In addition, urine flow increased from 4 +/- 6 ml/hr to 314 +/- 237 ml/hr (P less than 0.05), and subjective improvement was noted in all subjects. Undesirable effects observed were hypokalemia (all subjects), supraventricular tachycardia (one subject), and ventricular ectopic beats (three subjects), which responded to potassium replacement and other treatments. All patients required prolonged maintenance infusion to maintain adequate hemodynamic and clinical response. Four patients were weaned off from maintenance therapy after a mean duration of 4.8 days and eventually were discharged from the hospital.(ABSTRACT TRUNCATED AT 250 WORDS)
We report our experience with the use of a USCI Sones catheter curve A type 1 (7540) to cross the aortic valves of 45 patients with clinically significant aortic stenosis. The technique was successful in all our patients with a fluoroscopic time of less than 3 min. A gradient of up to 200 mmHg across the aortic valve area was recorded, and the smallest valve area calculated was less than 0.2 cm2. The method obviated the need for a guidewire and satisfactory left ventriculograms were obtained. No major complication was observed. We conclude that the technique is a simple, rapid, and safe means of obtaining left ventricular hemodynamic and angiographic information in patients with aortic stenosis of various degrees of severity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.