PurposeRecent data indicate that sensitization to mold contributes to the severity and persistence of asthma. In this study, we investigated the relationships between sensitization to mold and lung function parameters in children with asthma.MethodsWe retrospectively reviewed clinical data from 551 asthmatic subjects. We selected subjects who met clinical diagnostic criteria of asthma. Their spirometry, methacholine challenge tests, and measurements of blood eosinophils, serum IgE, eosinophil cationic protein (ECP) and fractional exhaled nitric oxide (FeNO) results were included. Skin prick testing (SPT) results with 13 common aeroallergens in Korea including house dust mites, animal dander, pollen, cockroach and mold were reviewed. Subjects were divided into 3 groups according to their SPT results. Subjects who showed no positive result to any aeroallergen were designated as group 1 (non-sensitized). Group 2 represented subjects who were sensitized to aeroallergens other than mold (other allergen-sensitized) and group 3 included subjects who were sensitized to mold allergens (mold-sensitized).ResultsAmong the 551 asthmatic subjects, 67 (12.2%) were sensitized to mold and 366 (66.4%) were sensitized to other aeroallergens. The log mean IgE levels were higher in groups 2 (5.96±1.14 IU/mL) and 3 (5.81±0.97 IU/mL) compared to group 1 (3.88±1.68 IU/mL). Blood eosinophils, ECP and FeNO concentrations were significantly higher in groups 2 and 3, but no significant difference was found between the 2 groups. The mean FEV1 value was significantly lower in group 3 (86.9±12.1%pred) than in groups 2 (92.0±14.8%pred) and 1 (93.4±15.4%pred). The log mean methacholine PC20 was significantly lower in group 3 (0.08±1.91 mg/mL) than in groups 2 (1.31±1.69 mg/mL) and 1 (2.29±1.66 mg/mL).ConclusionsWe observed a differential association between mold and other aeroallergen sensitization, and severity of asthma. Sensitization to mold is associated with lower lung function and increased airway hyper-responsiveness in children with asthma. Mold sensitization could be an important factor determining asthma severity particularly airflow limitation in children.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.